首页> 外文期刊>浙江大学学报(英文版)(A辑:应用物理和工程) >Study on performance of a packed bed latent heat thermal energy storage unit integrated with solar water heating system
【24h】

Study on performance of a packed bed latent heat thermal energy storage unit integrated with solar water heating system

机译:结合太阳能热水系统的填充床潜热蓄热单元性能研究

获取原文
获取原文并翻译 | 示例
       

摘要

In thermal systems such as solar thermal and waste heat recovery systems, the available energy supply does not usually coincide in time with the process demand. Hence some form of thermal energy storage (TES) is necessary for the most effective utilization of the energy source. This study deals with the experimental evaluation of thermal performance of a packed bed latent heat TES unit integrated with solar flat plate collector. The TES unit contains paraffin as phase change material (PCM) filled in spherical capsules, which are packed in an insulated cylindrical storage tank. The water used as heat transfer fluid (HTF) to transfer heat from the solar collector to the storage tank also acts as sensible heat storage material. Charging experiments were carried out at varying inlet fluid temperatures to examine the effects of porosity and HTF flow rate on the storage unit performance. The performance parameters such as instantaneous heat stored, cumulative heat stored, charging rate and system efficiency are studied. Discharging experiments were carried out by both continuous and batchwise processes to recover the stored heat, and the results are presented.
机译:In thermal systems such as solar thermal and waste heat recovery systems, the available energy supply does not usually coincide in time with the process demand. Hence some form of thermal energy storage (TES) is necessary for the most effective utilization of the energy source. This study deals with the experimental evaluation of thermal performance of a packed bed latent heat TES unit integrated with solar flat plate collector. The TES unit contains paraffin as phase change material (PCM) filled in spherical capsules, which are packed in an insulated cylindrical storage tank. The water used as heat transfer fluid (HTF) to transfer heat from the solar collector to the storage tank also acts as sensible heat storage material. Charging experiments were carried out at varying inlet fluid temperatures to examine the effects of porosity and HTF flow rate on the storage unit performance. The performance parameters such as instantaneous heat stored, cumulative heat stored, charging rate and system efficiency are studied.Discharging experiments were carried out by both continuous and batchwise processes to recover the stored heat, and the results are presented.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号