The electromotive force (EMF) changes in type K heavy gauge sheathed thermocouple cables was investigated. To cope with this discrepancy owing to EMF steep reduction and understand the difference between type K heavy gauge sheathed thermocouple cables and small ones, the affects of EMF from sheath pipe, drawing times, annealing temperature, annealing time and annealing way were mainly studied and appropriately analyzed. The results show the change in the thermal EMF is related with the residual stress and crystal defects, which are imparted by cold work during manufacture. The affects of cold work can be removed by annealing. Finally, a feasible way of fabricating heavy gauge sheathed thermocouples was suggested according to practical situation.