首页> 中文期刊>北京航空航天大学学报 >用于热控涂层性能原位测试的辐射计设计

用于热控涂层性能原位测试的辐射计设计

     

摘要

To solve the problem of thermal control coatings degradation in space environment,it is necessary to study coatings degradation law in simulated space environment,thus a radiometer design based on calorimetry was proposed for in situ measurement of thermal control coatings solar absorptance.The radiometer structure was designed according to the requirement of in situ measurement.By conducting thermal analysis on radiometer,the heat transfer equations were built and a calculation model based on transient thermal equilibrium was established by energy conservation principle.An SR107 thermal control coating was tested in isoperibol.The experiment result shows a within 2% relative error between the solar absorptance of SR107 and the coating calibration value,with a 6.3% measurement uncertainty.The result validates the effectiveness of the experiment.%针对空间环境中热控涂层性能退化的问题,提出一种模拟空间环境中利用测热法实现热控涂层太阳吸收率原位测试的辐射计设计方案.结合模拟空间环境的测试要求,进行辐射计的原理设计与理论研究;对辐射计进行结构热分析,建立辐射计测试过程中各项换热的计算式,从而得到辐射计的瞬态计算模型.恒温测试环境下利用辐射计对SR107热控涂层进行了测试.实验结果表明:辐射计测试的SR107热控涂层太阳吸收率值与该涂层的标定值之间的相对误差在2%以内,测试的不确定度为6.3%,实验结果验证了该测试方法的有效性.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com