AIM:To investigate the effects of diode laser treatment on ocular biometric parameters in premature infants with retinopathy of prematurity(ROP).METHODS:Premature infants who received diode laser treatment for ROP(n=68)and premature infants with spontaneous regressed ROP without treatment(n=50)were performed longitudinal ocular biometric measurements including anterior chamber depth,lens thickness and axial length as follows:1 d prior to laser treatment,and 3,6,9,and 12 mo after the laser treatment.RESULTS:The mean birth weight,gestational age and initial examination time values were 936.53±302.07 g,26.66±2.42 wk,36.26±2.73 wk in the treatment group and 959.78±260.08 g,27.28±2.10 wk,36.56±2.54 wk in the control group.There was no statistically significant difference in these demographic characteristics of the groups.Anterior chamber depth,lens thickness and axial length demonstrated statistically significant linear increases during the study period in the two groups(P<0.001 for each).There were no statistically significant differences between the two groups in terms of anterior chamber depth after laser treatment.Measurements of the lens thickness at 9 th and 12 th months(9 th month 3.70±0.22 vs 3.60±0.21 mm,P=0.017;12 th month 3.81±0.21 vs 3.69±0.22 mm,P=0.002)and the axial length at 12 th month(19.35±0.79 vs 19.13±0.54 mm,P=0.031)after laser treatment were statistically higher in the treatment group.CONCLUSION:Diode laser retinal photocoagulation treatment in premature infants seems to increase the lens thickness and axial length.
机译:目的:探讨二极管激光治疗在早产儿(ROP)视网膜病变的早产儿对眼生物识别参数的影响。方法:接受ROP(n = 68)的二极管激光治疗和早期婴儿的早产儿没有治疗(n = 50)进行纵向眼部生物测量,包括前腔深度,透镜厚度和轴向长度,如下所示:在激光治疗之前1 d,并在激光治疗后3,6,9和12 mo。结果:平均值出生体重,妊娠期和初始检查时间值为936.53±302.07g,治疗组中的36.26±2.73周,36.26±2.73周,959.78±260.08g,27.28±2.10 wk,控制组中36.56±2.54周。在这些人口统计特征中没有统计学显着差异。静脉室深度,透镜厚度和轴向长度在两组中的研究期间表现出统计学上显着的线性增加(每次P <0.001).t以下在激光治疗后的前房深度方面没有两组之间的统计学上显着差异。9月9日和12月的镜片厚度释放(第9个月3.70±0.22 Vs 3.60±0.21 mm,P = 0.017; 12 3.81±0.21 vs 3.69±0.22 mm,p = 0.002)和在治疗组中激光治疗后12个月(19.35±0.79 Vs,p = 0.031)的轴向长度在治疗组中均高于统计学上升。结论:二极管激光视网膜光凝治疗在早产似乎增加了透镜厚度和轴向长度。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号