首页> 外文期刊>国际眼科杂志:英文版 >Comparison of visual quality in cataract patients with low astigmatism after ART2 or ReSTOR intraocular lens implantation
【24h】

Comparison of visual quality in cataract patients with low astigmatism after ART2 or ReSTOR intraocular lens implantation

机译:ART2或ReSTOR人工晶状体植入术后低散光白内障患者的视觉质量比较

获取原文
获取原文并翻译 | 示例
       

摘要

AIM: To compare visual quality in cataract patients with low corneal astigmatism who underwent intraocular lens(IOL) implantation, and evaluate effects of low levels of astigmatism on visual outcomes in multifocal pseudophakic eyes.METHODS: This retrospective review of clinical records comprised patients with preoperative regular corneal astigmatism of 0.75-1.0 diopters(D) with-the-rule or 0.5-0.75 D against-the-rule who had uneventful cataract surgery and AcrySof IQ ReSTOR Toric-2 IOL(ART2) or AcrySof IQ ReSTOR IOL(ReSTOR) implantation. Retrospective data collection included postoperative ART2 axis rotation, uncorrected astigmatism, uncorrected entire visual acuities, distance corrected entire visual acuities, average modulation transfer function(aMTF), Strehl ratio(SR), spectacle independence, and patient satisfaction between groups.RESULTS: Mean ART2 axis rotation was 3.12°±0.70°. No secondary surgery was required to realign IOL axis. Residual astigmatism values were-0.18±0.07 D and-0.91±0.25 D in groups ART2 and ReSTOR(P<0.05). Three months postoperatively, the mean uncorrected distant, intermediate, and near visual acuities of group A were 0.01±0.05, 0.05±0.07, 0.02±0.07 logMAR, respectively;these were better than those of group R, which were 0.08±0.06, 0.15±0.12, and 0.09±0.08 logMAR, respectively(P<0.05). aMTF, SR, and spectacle independence rates were not significantly different. All patients were satisfied with postoperative results.CONCLUSION: ART2 is more suitable than ReSTOR for cataract patients with regular corneal astigmatism 0.75-1.0 D with-the-rule or 0.5-0.75 D against-the-rule.
机译:目的:比较接受人工晶状体(IOL)植入的角膜散光度低的白内障患者的视觉质量,并评估低散光度对多焦点假晶状体眼的视觉效果的影响。方法:这项回顾性临床研究包括术前患者规则角膜散光为0.75-1.0屈光度(D),无规则白内障手术且AcrySof IQ ReSTOR Toric-2 IOL(ART2)或AcrySof IQ ReSTOR IOL(ReSTOR)的规则或0.5-0.75 D的规则植入。回顾性数据收集包括术后ART2轴旋转,未矫正散光,未矫正整个视力,距离矫正整个视力,平均调制传递函数(aMTF),斯特列尔比(SR),眼镜独立性和组间患者满意度。轴旋转为3.12°±0.70°。无需重新手术即可重新调整IOL轴。 ART2组和ReSTOR组的残余像散值为-0.18±0.07 D和-0.91±0.25 D(P <0.05)。术后三个月,A组的平均未矫正远,中,近视力分别为logMAR的0.01±0.05、0.05±0.07、0.02±0.07,优于R组的0.08±0.06、0.15。 logMAR分别为±0.12和0.09±0.08 logMAR(P <0.05)。 aMTF,SR和眼镜独立率没有显着差异。结论:ART2较常规规则性角膜散光0.75-1.0 D或规则性0.5-0.75 D的白内障患者比ReSTOR更适合。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号