AIM:To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis(LASIK). METHODS:One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea:steep keratometry(Ks),flat keratometry(Kf),mean keratometry(Km),and astigmatism(Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation(Sw)the coefficient of repeatability(R),the coefficient of variation(Co V),and the intraclass correlation coefficient(ICC). Agreement between instruments was tested with the BlandAltman method by calculating the 95% limits of agreement(95% Lo A).RESULTS:In keratoconic eyes,the intra-examiner and inter-examiner ICC were >0.95. As compared with measurement by high-resolution Placido disk-based topography,the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf(0.32 vs 0.88),Ks(0.61 vs 0.88),and Km(0.32 vs 0.84)but higher for Ks-Kf(0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% Lo A were-1.28 to +0.55 for Kf,-1.36 to +0.99 for Ks,-1.08 to +0.50 for Km,and-1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes,the intra-examiner andinter-examiner ICC were >0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf,0.21 vs 0.88 for Ks,0.17 vs 0.86 for Km,and 0.28 vs 0.33 for Ks-Kf. The inter-examiner R was 0.09 vs 0.64 for Kf,0.15 vs 0.56 for Ks,0.09 vs 0.59 for Km,and 0.18 vs 0.23 for Ks-Kf. The 95% Lo A were-0.54 to +0.58 for Kf,-0.51 to +0.53 for Ks and Km,and-0.28 to +0.27 for Ks-Kf. CONCLUSION:As compared with Placido disk-based topography,the high-resolution rotating Scheimpflug camera provides more repeatable and reproducible measurements of Ks,Kf and Ks in keratoconic and post-LASIK eyes. Agreement between instruments is fair in keratoconus and very good in post-LASIK eyes.
机译:目的:比较高分辨率基于Placido盘的地形测量结果与高分辨率旋转Scheimpflug相机的测量结果的可重复性/可重复性,并评估两种仪器在测量圆锥角膜和激光照射后眼睛角膜屈光度之间的一致性。原位角膜磨镶术(LASIK)。方法:该前瞻性观察研究包括36例圆锥角膜患者和20例接受LASIK手术的受试者的一只眼睛。两名独立的检查员以随机的顺序工作,用两种仪器对每只眼睛进行了三次测量。测量角膜前缘的四个参数:陡度角膜曲率法(Ks),扁平角膜曲率法(Kf),平均角膜曲率(Km)和散光(Ks-Kf)。通过计算受试者内部标准差(Sw),重复性系数(R),变异系数(Co V)和组内相关系数(ICC)来评估被检查者内部和被检查者之间的可重复性。通过BlandAltman方法测试仪器之间的一致性,计算出95%的一致性极限(95%Lo A)。结果:圆锥角膜内检查者和检查者间ICC均大于0.95。与高分辨率基于Placido磁盘的地形测量相比,高分辨率旋转Scheimpflug相机的内部检查器R的Kf(0.32 vs 0.88),Ks(0.61 vs 0.88)和Km(0.32 vs 0.84)更低。 ),但Ks-Kf较高(0.70对0.57)。对于使用高分辨率旋转Scheimpflug相机测量的所有参数,检查者间R值均较低。 95%Lo A的Kf为1.28至+ 0.55,Ks为1.36至+ 0.99,Km为1.08至+ 0.50,Ks-Kf为1.11至+1.48。在LASIK术后眼睛中,检查者内部和检查者间ICC对于所有参数均> 0.87。对于使用高分辨率旋转Scheimpflug相机测量的所有参数,内部检查者和内部检查者R均较低。内部检查者R对于Kf为0.17对0.88,对于Ks为0.21对0.88,对于Km为0.17对0.86,对于Ks-Kf为0.28对0.33。审查员R对Kf分别为0.09对0.64,Ks对0.15对0.56,Km对0.09对0.59,对Ks-Kf对0.18对0.23。 Kf的95%Lo A为-0.54至+ 0.58,Ks和Km为-0.51至+ 0.53,Ks-Kf为-0.28至+0.27。结论:与基于Placido盘片的地形相比,高分辨率旋转Scheimpflug相机在圆锥角膜和LASIK术后眼睛中可提供更可重复和可再现的Ks,Kf和Ks测量。圆锥角膜中器械之间的一致性是很好的,并且在LASIK术后眼睛中是非常好的。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号