首页> 外文期刊>国际煤炭科学技术学报(英文) >Laboratory results of a 3rd generation roof bolter canopy air curtain for respirable coal mine dust control
【24h】

Laboratory results of a 3rd generation roof bolter canopy air curtain for respirable coal mine dust control

机译:用于可吸入煤矿粉尘控制的第三代屋顶锚杆雨棚气幕的实验室结果

获取原文
获取原文并翻译 | 示例
       

摘要

Testing was completed on an earlier roof bolter CAC that used slots to provide a perimeter airflow.NIOSHtested it due to its unique design that differed from canopies that provided uniform airflow.Based upon NIOSH recommendations from the earlier testing,a 3rd generation roof bolter CAC has been developed by J.H.Fletcher & Co.Thechanges to this CAC involve design modifications to the plenum outlets,using a single row of outlets on the perime ter and a different material for the plenum.This laboratory testing was a continuation of the original perimeter slotted CAC design.Using gravimetric and instantaneous sampling of respirable dust concentrations underneath and outside of the CAC,the laboratory testing was completed using three different blower fans that delivered differing airflows.The maximum plenum airflow velocities ranged from 2.34 to 3.64 m/s (460-716 fpm).Results showed plenum respirable dust concentrations ranging from 34.6% to 49.3% lower than respirable dust concentrations outside the plenum protection zone,thus showing an improvement in protection for the roof bolter operators.
机译:第三代屋顶锚杆CAC在较早的屋顶锚杆CAC上完成了测试,该CAC使用插槽提供周边气流.NIOSH因其独特的设计与提供均匀气流的顶篷不同而进行了测试。此CAC的更改涉及对气室出水口的设计修改,使用穿孔器上的单排出水口和用于气室的不同材料。此实验室测试是对原始周边开槽的CAC的延续设计使用CAC内部和外部的可吸入粉尘浓度的重量分析和瞬时采样,使用三个提供不同气流的不同鼓风机完成实验室测试,最大通风流速为2.34至3.64 m / s(460-716) fpm)。结果显示,通风系统可吸入粉尘浓度比可吸入粉尘浓度低34.6%至49.3%。在气室保护区域之外,因此显示了对屋顶锚杆机操作员的保护得到了改善。

著录项

  • 来源
    《国际煤炭科学技术学报(英文)》 |2019年第001期|15-26|共12页
  • 作者单位

    Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, 626 Cochrans Mill Rd., Pittsburgh, PA 15236, USA;

    Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, 626 Cochrans Mill Rd., Pittsburgh, PA 15236, USA;

    Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, 626 Cochrans Mill Rd., Pittsburgh, PA 15236, USA;

    Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, 626 Cochrans Mill Rd., Pittsburgh, PA 15236, USA;

    J.H Fletcher & Co., Inc., 402 High St., Huntington,WV 25705, USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-19 04:27:21