首页> 中文期刊> 《国际眼科杂志 》 >Keratograph 5M眼表综合分析仪观察小梁切除术后泪膜的早期变化

Keratograph 5M眼表综合分析仪观察小梁切除术后泪膜的早期变化

             

摘要

AlM: To observe the early tear film changes after trabeculectomy using Keratograph 5M.METHODS:Fourty-one patients (46 eyes) of glaucoma who underwent trabeculectomy were involved. First tear break up time ( FTBUT ) , average tear break up time (ATBUT), non-invasive tear meniscus height (NlTMH), lipid layer thickness and meibomian gland scores were measured at 1d preoperatively and at 1d, 1wk, 1mo postoperatively.RESULTS:At 1d, 1wk and 1mo postoperatively, FTBUT and ATBUT decreased greatly (P0. 05). CONCLUSlON: Keratograph 5M could be used to evaluate tear film function rapidly and accurately. Trabeculectomy significantly alters tear film stability and tear secretion in the short term after operation.%目的:运用Keratograph 5 M眼表综合分析仪观察小梁切除术后泪膜的早期变化。方法:收集青光眼患者41例46眼,分别于小梁切除术前1d,术后1d;1wk;1mo 行第一次泪膜破裂时间( first tear break up time,FTBUT)、平均泪膜破裂时间( average tear break up time,ATBUT)、非侵入式泪河高度( non-invasive tear meniscus height,NITMH)、脂质层厚度分级及睑板腺完整度评分检查。结果:与术前1 d 相比,术后1 d;1 wk;1 mo 的 FTBUT、ATBUT缩短(P0.05)。结论:Keratograph 5 M眼表综合分析仪可以快速、精确地评估泪膜的功能。青光眼小梁切除术在术后短期内可对泪膜的稳定性及泪液的分泌量产生不良影响。