首页> 外文期刊>高技术通讯(英文版) >Fabrication and performance evaluation of the thermoelectric generation and performance measuring system
【24h】

Fabrication and performance evaluation of the thermoelectric generation and performance measuring system

机译:热电发电和性能测量系统的制造和性能评估

获取原文
获取原文并翻译 | 示例
       

摘要

A novel thermoelectric generating and performance measuring system (TGPMS) was designed and fabricated. TGPMS can not only achieve the function of thermoelectric generation, but also measure the thermoelectric performance parameters of the bismuth-telluride-based thermoelectric device accurately. These thermoelectric performance parameters mainly include the dependence of the Seebeck coefficient of the thermoelectric device on the device's temperature in the low temperature range (about 40~190℃), and the dependence of the power output and thermoelectric conversion efficiency on the temperature difference or output load. With the optimum load, the optimal value of the power output is 3.39W when the temperature difference reaches 231.2℃, and the optimal value of the conversion efficiency is 3.22% when the temperature difference reaches 208.9℃. TGPMS provides an experimental foundation for the application of the thermoelectric generators in the space field.
机译:设计和制造了一种新型热电发电和性能测量系统(TGPMS)。 TGPM不仅可以实现热电一代的功能,而且精确地测量基于碲化物的热电装置的热电性能参数。这些热电性能参数主要包括热电装置在低温范围内(约40〜190℃)的温度上的塞贝克系数的依赖性,以及功率输出和热电转换效率对温差或输出的依赖性加载。随着最佳负载,当温差达到231.2℃时,电源输出的最佳值为3.39W,当温差达到208.9℃时,转化效率的最佳值为3.22%。 TGPMS为在空间场中的应用提供了一种实验基础。