首页> 中文期刊>强激光与粒子束 >10 B丰度变化对可溶硼浓度监测计算的影响分析

10 B丰度变化对可溶硼浓度监测计算的影响分析

     

摘要

在机组运行过程中,硼表硼浓度与化学分析硼浓度会出现一定偏差,根据秦山第二核电厂几台机组的实际运行数据整理出该硼浓度偏差的具体数据,并通过对比对应时间内的10 B 丰度变化情况,分析10 B丰度变化对该偏差的影响,得出该偏差主要是受10 B变化的影响且在机组寿期中达到最大的结论,并针对该现象对机组运行提出建议。同时采用 ORIENT对考虑了10 B丰度变化的理论硼浓度进行计算,并通过与化学分析硼浓度的对比得出该计算结果是可靠的,由此可以更加准确地预测、跟踪计算堆芯硼浓度的变化。%The boric acid concentration measured from boron meter and chemical analysis deviates from each other in the process of reactor unit operation.In this paper,we use the experimental data from QSⅡ nuclear power plant to analyze the influ-ence of 10 B abundance on the deviation.We find out that the deviation will reach a maximum value during the MOL,and some ad-vice on the operation of the plant is proposed according to this phenomenon.What’s more,we calculate the boric acid concentra-tion through ORIENT and verify its reliability by comparison with chemical analysis.As a consequence,we can predict and moni-tor the changes of boric acid concentration in the core of reactor more accurately.

著录项

  • 来源
    《强激光与粒子束》|2017年第1期|016022-1-016022-7|共7页
  • 作者单位

    中核核电运行管理有限公司 堆芯燃料处;

    浙江 嘉兴 314300;

    中核核电运行管理有限公司 堆芯燃料处;

    浙江 嘉兴 314300;

    中核核电运行管理有限公司 堆芯燃料处;

    浙江 嘉兴 314300;

    中核核电运行管理有限公司 堆芯燃料处;

    浙江 嘉兴 314300;

    中核核电运行管理有限公司 堆芯燃料处;

    浙江 嘉兴 314300;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类 反应堆参数监测系统;
  • 关键词

    硼表; 硼浓度偏差; 10 B丰度;