首页> 外文期刊>电气(英文版) >Analysis on Frequent Flameout of HG- 1025/18.2- YM6 Boiler
【24h】

Analysis on Frequent Flameout of HG- 1025/18.2- YM6 Boiler

机译:HG-1025 / 18.2- YM6锅炉频繁熄火分析

获取原文
获取原文并翻译 | 示例
       

摘要

Based on reason analyses for frequent flameout of HG-1025/18.2-YM6 boiler in a given power plant after coal quality variation, major factors such as unreasonable burner structure and inappropriate secondary air distribution were discussed in detail. A new mode of secondary air distribution was introduced to optimize the combustion performance, and a lower burner was retrofitted by increasing the relative distance between the primary air fuel rich-lean nozzles and reducing the size of waist air nozzles as well. As a result, the recirculating zone became more stable and the burner's combustion stability was improved.Practical operation shows that the modifications are so effective that the flameout problems caused by instable combustion never occur in operation.
机译:基于原因分析在煤炭质量变化之后给定电厂HG-1025 / 18.2-YM6锅炉频繁熄火的频繁燃烧器,详细讨论了不合理的燃烧器结构等主要因素和不合适的二级空气分布。引入了一种新的二次空气分布模式以优化燃烧性能,并且通过增加初级空气燃料浓贫喷嘴之间的相对距离并减小腰部空气喷嘴的尺寸,改装较低燃烧器。结果,再循环区变得更稳定,改善了燃烧器的燃烧稳定性。正常操作表明,修改如此有效,即由稳定燃烧引起的熄火问题永远不会发生在操作中。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号