BACKGROUND Intertrochanteric(IT)fracture is one of the most common fractures seen in an orthopaedic practice.Proximal femoral nailing(PFN)is a common modality of fixing IT femur fracture.We retrospectively studied whether a PFN with two proximal lag screws can be done without distal interlocking screws in the 31-A1 and 31-A2 fracture patterns according to the Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association(AO/OTA)guidelines for IT femur fractures.AIM To compare the outcomes of IT fractures(AO/OTA 31-A1 and 31-A2)treated by PFN with and without distal interlocking screws.METHODS We carried out a retrospective study of 140 patients in a tertiary care centre who had AO/OTA type 31-A1 and 31-A2 IT fractures.We divided the patients into two groups,in which one of the groups received distal interlocking screws(group 1)and the other group did not(group 2).The subjects were followed up for a mean period of 14 mo and assessed for radiological union time,fracture site collapse,mechanical stability of implant,and complications associated with the PFN with distal interlocking and without distal interlocking.Then,the results were compared.RESULTS PFN without distal interlocking screws has several advantages and gives better results over PFN with distal interlocking screws in the AO/OTA 31-A2 fracture pattern.However,similar results were observed in both groups with the fracture pattern AO/OTA 31-A1.In patients with fracture pattern AO/OTA 31-A2 treated by PFN without distal interlocking screws,there were minimal proximal lockrelated complications and no risk of distal interlock-related complications.The operative time,IITV radiation time and time to radiological union were reduced.These patients also had better rotational alignment of the proximal femur,and the anatomy of the proximal femur was well maintained.It was also noted that in the cases where distal interlocking was performed,there was a gradual decrease in neck shaft angle,which led to varus collapse and failure of bone-implant construct in 21.40%.CONCLUSION In fracture pattern AO/OTA 31-A2,PFN without distal interlocking had better results and less complications than PFN with distal interlocking.

相似文献

  • 中文文献
  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号