首页> 中文期刊> 《世界骨科杂志:英文版》 >Three-dimensional reconstructed magnetic resonance scans:Accuracy in identifying and defining knee meniscal tears

Three-dimensional reconstructed magnetic resonance scans:Accuracy in identifying and defining knee meniscal tears

         

摘要

AIM To determine whether three-dimensional(3D) reconstruction from conventional magnetic resonance imaging(MRI) is able to accurately detect a meniscal tear, and define the configuration.METHODS Thirty-three patients' 3T MRI scan data were collected and sagittal uni-planar 3D reconstructions performed from the preoperative MRI. There were 24 meniscal tears in 24 patients, and nine controls. All patients had arthroscopic corroboration of MRI findings. Two independent observers prospectively reported on all 33 reconstructions. Meniscal tear presence or absence was noted, and tear configuration subsequently categorised as either radial, bucket-handle, parrot beak, horizontal or complex.RESULTS Identification of control menisci or meniscal tear presence was excellent(Accuracy: observer 1 = 90.9%; observer 2 = 81.8%). Of the tear configurations, bucket handle tears were accurately identified(Accuracy observer 1 and 2 = 80%). The remaining tear configurations were notaccurately discernable.CONCLUSION Uni-planar 3D reconstruction from 3T MRI knee scan sequences are useful in identifying normal menisci and menisci with bucket-handle tears. Advances in MRI sequencing and reconstruction software are awaited for accurate identification of the remaining meniscal tear configurations.