首页> 中文期刊>世界骨科杂志:英文版 >Managing extremely distal periprosthetic femoral supracondylar fractures of total knee replacements-a new PHILOS-ophy

Managing extremely distal periprosthetic femoral supracondylar fractures of total knee replacements-a new PHILOS-ophy

     

摘要

We report two cases where a proximal humeral locking plate was used for the fixation of an extremely distal, type Ⅲ peri-prosthetic femoral fractures in relation to a total knee replacement(TKR). In each case there was concern regarding the fixation that could be achieved using the available anatomic distal femoral plates due to the size and bone quality of distal fragment. The design of the Proximal Humeral Internal Locking System(PHILOS) allows nine 3.5-mm locking screws to be placed over a small area in multiple directions. This allowed a greater number of fixation points to be achieved in the distal fragment. Clinical and radiological short-term follow-up(6-12 mo) has been satisfactory in both cases with no complications. We suggest the use of this implant for extremely distal femoral fractures arising in relation to the femoral component of a TKR.

著录项

相似文献

  • 中文文献
  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有