首页> 中文期刊>高电压技术 >Separating Overlapped Peaks of SF6 Decomposed Products Based on Iterative Curve-fitting Method

Separating Overlapped Peaks of SF6 Decomposed Products Based on Iterative Curve-fitting Method

     

摘要

The SF6 decomposed products are very alike,so the peaks of the SF6 decomposed products are overlapped.It make us hard to quantitatively calculate.This paper introduced a method to separate the overlapped chromatogram peaks with iterative curve-fitting and Gauss function,and deduced the formula of the iterative curve-fitting;provided a method to calculate the initial value of the peaks intensity and width by iterative formula,and confirm the final peaks intensity and width to separate the overlapped signals.By the analysis of the real chromatogram data,it proved the validity of this method on the main components used in distinguishing the GIS internal defects.This method overcomes the influence of SF6 peak to the other thin concentration peaks,so it can be used in the study of the quantitative analysis of the decomposed products on different failures and different voltages.

著录项

相似文献

  • 中文文献
  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号