首页> 中文期刊>世界放射学杂志:英文版(电子版) >Diagnostic problems in two-dimensional shear wave elastography of the liver

Diagnostic problems in two-dimensional shear wave elastography of the liver

     

摘要

Two-dimensional shear wave elastography(2D-SWE)is used in the clinical setting for observation of the liver.Unfortunately,a wide spectrum of artifactual images are frequently encountered in 2D-SWE,the precise mechanisms of which remain incompletely understood.This review was designed to present many of the artifactual images seen in 2D-SWE of the liver and to analyze them by computer simulation models that support clinical observations.Our computer simulations yielded the following suggestions:(1)When performing 2D-SWE in patients with chronic hepatic disease,especially liver cirrhosis,it is recommended to measure shear wave values through the least irregular hepatic surface;(2)The most useful 2D-SWE in patients with focal lesion will detect lesions that are poorly visible on B-mode ultrasound and will differentiate true tumors from pseudo-tumors(e.g.,irregular fatty change);and(3)Measurement of shear wave values in the area posterior to a focal lesion must be avoided.