A retrospective review was made of intraoperative femoral fracture prevalence in seventy nine consecutive, cementless, fully HA-coated stems used for revision hip arthroplasty. Three patients were lost to follow up. Intraoperative fracture occurred in 15 (20%) femurs. Fractures occurred during cement removal (3/15) or insertion of the implant (12/15). All fractures were identified using intraoperative biplane X-ray, and were treated during the same operation. The clinical outcome of both groups (with or without fractures) was similar. The risk of intraoperative fracture was not statistically related to any demographic features or operative technique. Intraoperative radiographs are therefore mandatory in revision hip arthroplasty in order to diagnose and treat the common complication of femur fracture appropriately.