首页> 中文期刊> 《美国分析化学(英文)》 >Use of Cucurbit 6 Uril as a Modifier in the Electrochemical Determination of Antitumor Platinum (II) Complex: iTrans/i-PtClsub2/sub(Dimethylamine) (Isopropylamine). Application to Biological Samples

Use of Cucurbit 6 Uril as a Modifier in the Electrochemical Determination of Antitumor Platinum (II) Complex: iTrans/i-PtClsub2/sub(Dimethylamine) (Isopropylamine). Application to Biological Samples

         

摘要

A square wave voltammetry (DPV) method for trans-Pt[Cl2(Dimethylamine)(isopropylamine)] determination is developed. To this end, all the chemical and instrumental variables affecting the determination of trans-Pt[Cl2(Dimethylamine) (isopropylamine)] are optimized. From studies of the mechanisms governing the electrochemical response of trans-Pt[Cl2(Dimethylamine)(isopropylamine)], it was concluded that it was an electrochemically reversible system with an adsorptive oxidation phenomenon. Under optimal conditions, the variation of analytical signal (Ip) with trans-Pt[Cl2(Dimethylamine)(isopropylamine)] concentration was linear in the 0.05 μg·mL-1 to 10 μg·mL-1 range, with a LOD 91 μg·mL-1 of and a LOQ of 303 μg·mL-1, a RSD 1.10% and Er 0.72%. The optimized method was applied to the determination of trans-Pt[Cl2(Dimethylamine)(isopropylamine)] in biological fluids, in human urine and synthetic urine.