首页> 中文期刊> 《电磁分析与应用期刊(英文)》 >Detection of Blood Traces in Human Pericardial Fluid Using Microwaves

Detection of Blood Traces in Human Pericardial Fluid Using Microwaves

         

摘要

This communication reports a novel method of analyzing pericardial fluid and finding blood traces present based on the measurement of the dielectric properties at microwave frequencies. The experiment was performed by cavity perturbation method in the S-band of microwave frequency with the pericardial fluid from healthy persons as well as from patients suffering from pericardial bleeding. It is noted that considerable variation in the dielectric properties of patient samples with the normal healthy samples and these measurements were in good agreement with clinical analysis. This measurement technique and the method of extraction of pericardial fluid are simple and both are non invasive. These results give light to an alternative in-vitro method of diagnosing onset pericardial bleeding abnormalities using microwaves without surgical procedure.