首页> 中文期刊>世界骨科杂志:英文版 >Errors in visual estimation of flexion contractures during total knee arthroplasty

Errors in visual estimation of flexion contractures during total knee arthroplasty

     

摘要

AIM: To quantify and reduce the errors in visual estimation of knee flexion contractures during total knee arthroplasty(TKA).METHODS: This study was divided into two parts: Quantification of error and reduction of error. To quantify error, 3 orthopedic surgeons visually estimated preoperative knee flexion contractures from lateral digital images of 23 patients prior to and after surgical draping. A repeated-measure analysis of variance was used to compare the estimated angles prior to and following the placement of the surgical drapes with the true knee angle measured with a long-arm goniometer. In an effort to reduce the error of visual estimation, a dual set of inclinometers was developed to improve intraoperative measurement of knee flexion contracture during TKA. A single surgeon performed 6 knee extension measurements with the device during 146 consecutive TKA cases. Three measurements were taken with the desired tibial liner trial thickness, and 3 were taken with a trial that was 2 mm thicker. An intraclass correlation coefficient(ICC) was calculated to assess the testretest reliability for the 3 measurements taken with the desired liner thickness, and a paired t test was used to determine if the knee extension measurements differed when a thicker tibial trial liner was placed.RESULTS: The surgeons significantly overestimated flexion contractures in 23 TKAs prior to draping and significantly underestimated the contractures after draping(actual knee angle = 6.1°± 6.4°, pre-drape estimate = 6.9°± 6.8°, post-drape estimate = 4.3°± 6.1°, P = 0.003). Following the development and application of the measurement devices, the measurements were highly reliable(ICC = 0.98), and the device indicated that 2.7°± 2.2° of knee extension was lost with the insertion of a 2 mm thicker tibial liner. The device failed to detect a difference in knee extension angle with the insertion of the 2 mm thicker liner in 9/146 cases(6.2%).CONCLUSION: We determined the amount of error associated with visual estimation of knee flexion contractures, and developed a simple, reliable device and method to improve feedback related to sagittal alignment during TKA.

著录项

相似文献

  • 中文文献
  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号