Objective: To improve the detecting accuracy of chromosomal aneuploidy of fetus by non-invasive prenatal testing (NIPT) using next generation sequencing data of pregnant women’s cell-free DNA. Methods: We proposed the multi-Z method which uses 21 z-scores for each autosomal chromosome to detect aneuploidy of the chromosome, while the conventional NIPT method uses only one z-score. To do this, mapped read numbers of a certain chromosome were normalized by those of the other 21 chromosomes. Average and standard deviation (SD), which are used for calculating z-score of each sample, were obtained with normalized values between all autosomal chromosomes of control samples. In this way, multiple z-scores can be calculated for 21 autosomal chromosomes except oneself. Results: Multi-Z method showed 100% sensitivity and specificity for 187 samples sequenced to 3 M reads while the conventional NIPT method showed 95.1% specificity. Similarly, for 216 samples sequenced to 1 M reads, Multi-Z method showed 100% sensitivity and 95.6% specificity and the conventional NIPT method showed a result of 75.1% specificity. Conclusion: Multi-Z method showed higher accuracy and robust results than the conventional method even at low coverage reads.