首页> 外文期刊>外科学(英文) >Differences in the Length and Thickness of the Coracoacromial Ligament between Normal Shoulders and Shoulders with Rotator Cuff Tears
【24h】

Differences in the Length and Thickness of the Coracoacromial Ligament between Normal Shoulders and Shoulders with Rotator Cuff Tears

机译:正常肩膀和肩部肩胛骨泪液之间的鳞状韧带的长度和厚度的差异

获取原文
获取原文并翻译 | 示例
       

摘要

Although the relationship between the material properties of the coracoacromial ligament and rotator cuff tears has been clarified, it is difficult to evaluate these properties in the clinical setting. The purpose of this study was to clarify the relationship between rotator cuff tears and the length and thickness of the coracoacromial ligament in living shoulders, in order to assess the potential use of these parameters as clinical indicators of the possible risk or progression of rotator cuff tears. Thirty-five volunteers (46 shoulders, mean age: 52 years) were enrolled. The presence or absence of rotator cuff tears and the length and thickness of the coracoacromial ligament were evaluated by ultrasonography. Longitudinal images of the coracoacromial ligaments with the acromion and coracoid process as landmarks were obtained, and the lengths of the ligaments were measured using acoustic shadows as the index. On the same screens, the thicknesses at the center of the ligaments were measured. Ligaments in shoulders with a rotator cuff tear were significantly shorter than ligaments in shoulders without a rotator cuff tear (25.9 ± 2.5 mm vs. 28.6 ± 1.7 mm, respectively;P < 0.0001). There was no significant difference in the thicknesses of the ligaments. The length and thickness of the coracoacromial ligament of living shoulders were easily evaluated with ultrasonography in the present study, and the coracoacromial ligament was found to be significantly shorter in shoulders with a rotator cuff tear. The risk and progression of rotator cuff tears can be evaluated clinically by measuring the length of the coracoacromial ligament.
机译:虽然已经阐明了冠状曲线韧带和旋转箍泪的材料性质之间的关系,但难以评估临床环境中的这些性质。本研究的目的是阐明旋转箍撕裂撕裂和胶凝式韧带的长度和厚度之间的关系,以评估这些参数的潜在使用作为旋转袖口撕裂的可能风险或进展的临床指标。三十五名志愿者(46名肩膀,意思是年龄:52岁)。通过超声检查评估旋转箍泪撕裂的存在或不存在冠状动脉韧带的长度和厚度。获得具有肩谱和斜角工艺作为地标作为地标的纵向图像的纵向图像,并且使用声学阴影作为指标测量韧带的长度。在相同的屏幕上,测量韧带中心的厚度。带有转子箍撕裂的肩部的韧带显着短于肩部肩部撕裂的韧带(分别为25.9±2.5mm与28.6±1.7mm; p <0.0001)。韧带的厚度没有显着差异。在本研究中,在超声检查中容易评估生物肩的鳞状韧带的长度和厚度,并且对肩袖撕裂的肩膀上发现曲调韧带显着短。旋转袖口撕裂的风险和进展可以通过测量升性韧带的长度来临床评估。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号