首页> 外文期刊>金属材料研究(英文) >The Study on the Corrosion Behaviour of Welded and Unwelded Medium Carbon Steel in Sodium Chloride(Nacl)Solutions
【24h】

The Study on the Corrosion Behaviour of Welded and Unwelded Medium Carbon Steel in Sodium Chloride(Nacl)Solutions

机译:氯化钠(NaCl)溶液中焊接和未焊接中碳钢的腐蚀行为研究

获取原文
获取原文并翻译 | 示例
       

摘要

The research work was based on the study of the corrosion behaviour of the welded and un-welded medium carbon steel in sodium chloride solutions.The Sodium chloride solutions used are 1ml,2ml,3ml and 4ml for both welded and un-welded medium carbon steel in NaCl.The experiments were conducted in two ways,the weight loss analyses of measurements and using the electrochemical analyzer workstation to determine the potential dynamic of the samples.The samples for the weight loss measurements were prepared from rolled products obtained at the foundry shop.Two medium carbon steel materials were sourced with different chemical compositions as sample A and B.The materials were prepared to accommodate the experiments for the determination of welded and un-welded medium carbon steel.A total of sixty-eight(68)samples were produced,prepared and used for the weight loss measurements/analyses the experiments.Thirty-four of the samples each were prepared for both the welded and un-welded experiments.All the samples were produced and prepared through the use of various machining processes with the use of a lathe machine for planning,milling.Thirty-four(34)of the sample preparation were further welded in readiness of the experiments.Sixty-eight breakers were sourced for and used.Ten(10)other samples were used for the determination with the use of the electrochemical analyzer.The chemical compositions of the medium carbon steel were determined with the use of SPECTRO Analytical Instruments.A metallurgical inverted optical microscope was used to determine the microstructures of the materials.The Scanning Electron Microscopy with EDS was used to determine the morphologies of the materials.The thirty-four of the samples were welded this process was performed to determine the effects of welding on the material surrounding the weldments.These materials were made into sizes with the use of power hacksaw(i.e.2cm by 2cm).Other materials were prepared to 1cm x 1cm thickness from the same materials.The Tafel plot experiments and that of the open Circuit Potential Time(OCPT)were carried out with the use of Electrochemical Analyzer/Workstation.The Medium carbon steel materials were exposed for fifty-four(54)days,with an interval of 3days.The corrosion rates analyses were determined and the graphs of the corrosion rates(mm/yr.)and other parameters were used plotted against No of days exposed.
机译:研究工作是基于氯化钠溶液中焊接和未焊接中碳钢的腐蚀行为的研究。用于焊接和未焊接的中碳钢的氯化钠溶液是1ml,2ml,3ml和4ml在NaCl中。实验以两种方式进行,测量的重量损失分析并使用电化学分析仪工作站确定样品的潜在动态。减肥测量的样品由在铸造店获得的轧制产品制备。用不同的化学组合物作为样品A和B来源的两种中等碳钢材料。制备材料以适应焊接和未焊接介质碳钢的实验。制备总共68(68)个样品,制备并用于减肥测量/分析实验。为焊接和未焊接的实验制备各种样品.A通过使用各种加工工艺使用用于规划的车床机,铣削,铣削,铣削,在实验的准备内进一步焊接,通过使用各种加工工艺制备并制备样品。用于和使用的。(10)其他样品用于使用电化学分析仪的测定。使用光谱分析仪器测定中碳钢的化学组成。使用冶金倒光学显微镜确定材料的微观结构。使用EDS的扫描电子显微镜测定材料的形态。焊接三十四个样品进行该过程,以确定焊接对焊接周围材料的影响。这些方法用电力钢锯(IE2cm乘2cm)制成尺寸的材料。其他材料从同一个母体中制备1cm×1cm厚度使用电化学分析仪/工作站进行Tafel绘图实验和开放电路电位时间(OCPT)。介质碳钢材料暴露54天(54)天,间隔为3天确定腐蚀速率分析,并使用腐蚀速率(mm / yr。)和其他参数的图来绘制不暴露的天数。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号