首页> 中文期刊> 《计算机辅助绘图.设计与制造:英文版》 >Two fully automated data-driven 3D whole-breast segmentation strategies in MRI for MR-based breast density using image registration and U-Net with a focus on reproducibility

Two fully automated data-driven 3D whole-breast segmentation strategies in MRI for MR-based breast density using image registration and U-Net with a focus on reproducibility

         

摘要

Presence of higher breast density(BD)and persistence over time are risk factors for breast cancer.A quantitatively accurate and highly reproducible BD measure that relies on precise and reproducible whole-breast segmentation is desirable.In this study,we aimed to develop a highly reproducible and accurate whole-breast segmentation algorithm for the generation of reproducible BD measures.Three datasets of volunteers from two clinical trials were included.Breast MR images were acquired on 3T Siemens Biograph mMR,Prisma,and Skyra using 3D Cartesian six-echo GRE sequences with a fat-water separation technique.Two whole-breast segmentation strategies,utiliz-ing image registration and 3D U-Net,were developed.Manual segmentation was performed.A task-based analysis was performed:a previously developed MR-based BD measure,MagDensity,was calculated and assessed using automated and manual segmentation.The mean squared error(MSE)and intraclass correlation coefficient(ICC)between MagDensity were evaluated using the manual segmentation as a reference.The test-retest reproducibility of MagDensity derived from different breast segmentation methods was assessed using the difference between the test and retest measures(Δ_(2-1)),MSE,and ICC.The results showed that MagDensity derived by the registration and deep learning segmentation methods exhibited high concordance with manual segmentation,with ICCs of 0.986(95%CI:0.974-0.993)and 0.983(95%CI:0.961-0.992),respectively.For test-retest analysis,MagDensity derived using the regis-tration algorithm achieved the smallest MSE of 0.370 and highest ICC of 0.993(95%CI:0.982-0.997)when compared to other segmentation methods.In conclusion,the proposed registration and deep learning whole-breast segmentation methods are accurate and reliable for estimating BD.Both methods outperformed a previously developed algorithm and manual segmentation in the test-retest assessment,with the registration exhibiting superior performance for highly reproducible BD measurements.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号