首页> 中文期刊> 《中国物理:英文版》 >Combined effect of light intensity and temperature on the magnetic resonance linewidth in alkali vapor cell with buffer gas

Combined effect of light intensity and temperature on the magnetic resonance linewidth in alkali vapor cell with buffer gas

         

摘要

One of the peculiar phenomenons in non-zero magnetic resonance magnetometer is that,with the increase of the temperature,the magnetic resonance linewidth is narrowed at first instead of broadened due to the increasing collision rate.The magnetometer usually operates at the narrowest linewidth temperature to obtain the best sensitivity.Here,we explain this phenomenon quantitatively considering the nonlinear of the optical pumping in the cell and did experiments to verify this explanation.The magnetic resonance linewidth is measured using one amplitude-modulated pump laser and one continuous probe laser.The field is along the direction orthogonal to the plane of pump and probe beams.We change the temperature from 53 ℃ to 93 ℃ and the pumping light from 0.1 mW to 2 mW.The experimental results agree well with the theoretical calculations.

著录项

  • 来源
    《中国物理:英文版》 |2017年第6期|417-421|共5页
  • 作者单位

    School of Instrumentation Science and Opto-Electronics Engineering, Beihang University, Beijing 100191, China;

    School of Instrumentation Science and Opto-Electronics Engineering, Beihang University, Beijing 100191, China;

    School of Electronic and Information Engineering, Beihang University, Beijing 100191, China;

    School of Instrumentation Science and Opto-Electronics Engineering, Beihang University, Beijing 100191, China;

    School of Instrumentation Science and Opto-Electronics Engineering, Beihang University, Beijing 100191, China;

  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号