Two curved crystal spectrometers are set up on the "QiangGuang-1" generator to measure the z-pinch plasma spectra emitted from planar aluminum wire array loads.Kodak Biomax-MS film and an IRD AXUVHS5# array are employed to record time-integrated and time-resolved free-bound radiation,respectively.The photon energy recorded by each detector is ascertained by using the L-shell lines of molybdenum plasma.Based on the exponential relation between the continuum power and photon energies,the aluminum plasma electron temperatures are measured.For the time-integrated diagnosis,several "bright spots" indicate electron temperatures between(450 eV~520 eV)±35%.And for the time-resolved ones,the result shows that the electron temperature reaches about 800 eV±30%at peak power. The system satisfies the demand of z-pinch plasma electron temperature diagnosis on a~1 MA facility.