首页> 中文期刊> 《中华医学杂志(英文版)》 >Minimally invasive transforaminal lumbar interbody fusion aided with computer-assisted spinal navigation system combined with electromyography monitoring

Minimally invasive transforaminal lumbar interbody fusion aided with computer-assisted spinal navigation system combined with electromyography monitoring

         

摘要

Background Minimally invasive techniques are gaining wide-spread application in lumbar fusion surgery,because they may have advantage over conventional open surgery in approach-related morbidity.This research was aimed to evaluate the safety and accuracy of the techniques of minimally invasive transforaminal lumbar interbody fusion by using a computer-assisted spinal navigation system combined with electromyography monitoring.Methods Sixteen patients underwent minimally invasive transforaminal lumbar interbody fusion.A computer-assisted spinal navigation system and electromyography were used for guiding pedicle screw placement.The operative duration,blood loss,complications,and fluoroscopic time were recorded.Clinical outcome was assessed by Visual Analog Scale and Oswestry Disability Index.Radiographic images were obtained to evaluate the accuracy of pedicle screw placement and fusion rates.Results The Visual Analog Scale and Oswestry Disability Index scores were vastly improved postoperatively.A total of 64 pedicle screws were implanted and three were regarded as misplacement by post-operative CT scan.Three screw trajectories were adjusted according to intra-operative stimulus-evoked electromyography monitoring.The average fluoroscopy time in each patient was 31.8 seconds,which equals to 7.9 seconds per pedicle screw.No patients had instrument related neurological complications,infection,implant failure or revision.Successful fusion was found in all patients.Conclusions The combination of navigation system and real-time electromyography monitoring can make the minimally invasive operation more safe and accurate while decreasing radiation exposure time of the medical staff and patient and minimizing the chance and the degree of the pedicle screw misplacement.

著录项

  • 来源
    《中华医学杂志(英文版)》 |2012年第22期|3947-3951|共5页
  • 作者单位

    Department of Orthopaedics,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan,Hubei 430030,China;

    Department of Orthopaedics,the First People Hospital of Yichang,San-xia University,Yichang,Hubei 443000,China;

    Department of Orthopaedics,Beijing Chaoyang Hospital,Capital Medical University,Beijing 100020,China;

    Department of Orthopaedics,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan,Hubei 430030,China;

    Department of Orthopaedics,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan,Hubei 430030,China;

    Department of Orthopaedics,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan,Hubei 430030,China;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号