首页> 中文期刊> 《中华医学杂志(英文版)》 >Computer-driven automated weaning reduces weaning duration in difficult-to-wean patients

Computer-driven automated weaning reduces weaning duration in difficult-to-wean patients

         

摘要

Background Weaning difficulties occur in 31% of total intubated patients,and result in prolonged weaning duration.A computer-driven automated weaning system can perform a spontaneous breathing trial (SBT) automatically and display a message when the trial is successfully passed.Such a system might have a beneficial effect on difficult-to-wean patients.The aim of this study was to examine whether the computer-driven automated weaning system can accelerate discontinuation of mechanical ventilation and improve outcomes in difficult-to-wean patients.Methods This randomized controlled study included 39 difficult-to-wean patients who failed their first spontaneous breathing trial.Before initiating weaning,eligible patients were randomly allocated to wean by computer-driven automated weaning system (CDW group,n=19) or a physician-controlled local protocol (PW group,n=20).Weaning duration,defined as the time from inclusion until first extubation,was the primary endpoint.Secondary endpoints were total duration of mechanical ventilation,the length of intensive care unit (ICU) stay,the number of reintubations,the mortality rate in the ICU,the number of noninvasive ventilations,the number of complications in the ICU,and the number of ventilator-associated pneumonia cases.Results The weaning duration was reduced with the computer-driven weaning as compared with the usual protocol (median 29.0 hours vs.45.5 hours,P=0.044).Total duration of mechanical ventilation and duration of the ICU stay did not differ between the CDW and PW groups.There was no difference in the number of reintubations between the CDW and PW groups (3 and 4 patients,P=-0.732).The study groups showed comparable numbers of tracheostomy,selfextubations,ventilator-associated pneumonia,and non-invasive ventilation.Mortality in the ICU was similar in the CDW and the PW groups (21.1% vs.20.0%,P=-0.935).Conclusion The computer-driven automated weaning system can reduce weaning duration in difficult-to-wean patients as compared with a physician-controlled weaning protocol.

著录项

  • 来源
    《中华医学杂志(英文版)》 |2013年第10期|1814-1818|共5页
  • 作者单位

    Department of Critical Care Medicine, Nanjing Zhongda Hospital,Southeast University, Nanjing, Jiangsu 210009, China;

    Department of Critical Care Medicine, Nanjing Zhongda Hospital,Southeast University, Nanjing, Jiangsu 210009, China;

    Department of Critical Care Medicine, Nanjing Zhongda Hospital,Southeast University, Nanjing, Jiangsu 210009, China;

    Department of Critical Care Medicine, Nanjing Zhongda Hospital,Southeast University, Nanjing, Jiangsu 210009, China;

    Department of Critical Care Medicine, Nanjing Zhongda Hospital,Southeast University, Nanjing, Jiangsu 210009, China;

    Department of Critical Care Medicine, Nanjing Zhongda Hospital,Southeast University, Nanjing, Jiangsu 210009, China;

  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号