首页> 中文期刊> 《中华医学杂志(英文版)》 >Adenosine Sensitivity is Associated with Ablation Success Rate and Recurrence Rate with Nonirrigated Catheters in Patients with Ventricular Premature Contractions/Tachycardia from the Ventricular Outflow Tract

Adenosine Sensitivity is Associated with Ablation Success Rate and Recurrence Rate with Nonirrigated Catheters in Patients with Ventricular Premature Contractions/Tachycardia from the Ventricular Outflow Tract

         

摘要

Background:A high ablation success rate for ventricular arrhythmia (VA) from outflow tract has been achieved,but some of them cannot be eliminated from endocardium.We investigated the association between adenosine sensitivity and ablation success/recurrence rates with a nonirrigated or an irrigated catheter.Methods:According to adenosine test,all patients were divided into a sensitive group (S group) or an insensitive group (Ⅰ group).The patients of each group were randomized into a nonirrigated catheter (NA) subgroup or an irrigated catheter (IA) subgroup with a 2∶1 ratio.Results:In S group of 122 patients (84 in NA subgroup),the ablation success rate was similar between two subgroups (94.7% vs.90.5%,P > 0.05),but in Ⅰ group of 94 patients (60 in NA subgroup),it was higher in IA subgroup (94.1%) than that in NA subgroup (73.3%,P < 0.05).The success rate using nonirrigated catheter was significantly higher in S group (90.5%) than that in Ⅰ group (73.3%,P < 0.01),and the recurrence rate was lower in S group than that in Ⅰ group (1.3%,vs.13.6%,P < 0.05).On the contrary,the success rate and the recurrence rate using irrigated catheter were similar between S group and 1 group (94.7%,94.1%,P > 0.05,vs.2.8%,6.3%,P > 0.05).Conclusions:Adenosine insensitivity is associated with a lower success rate and a higher recurrence rate for VA patients undergoing nonirrigated catheter ablation.Thus,irrigated catheters should be the first choice for VA ablation in adenosine insensitive patients.

著录项

  • 来源
    《中华医学杂志(英文版)》 |2015年第2期|147-152|共6页
  • 作者单位

    Department of Cardiology, Xinhua Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai 200092, China;

    Department of Cardiology, Xinhua Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai 200092, China;

    Department of Cardiology, Xinhua Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai 200092, China;

    Department of Cardiology, Xinhua Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai 200092, China;

    Department of Cardiology, Xinhua Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai 200092, China;

    Department of Cardiology, Xinhua Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai 200092, China;

    Metropolitan Heart and Vascular Institute, Minneapolis, MN., USA;

  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号