Investigation and Analysis of Hemoglobin A1c Measurement Systems' Performance for 135 Laboratories in China

         

摘要

Background:Hemoglobin A1c (HbA1c) measurement is of great value for the diagnosis and monitoring of diabetes.Many manufacturers have developed various experiments to determine the HbAlc concentration.However,the longitudinal use of these tests requires strict quality management.This study aimed to analyze the quality of HbA1 c measurement systems in China using six sigma techniques to help improve their performances.Methods:A total of 135 laboratories were involved in this investigation in 2015.Bias values and coefficients of variation were collected from an HbA1c trueness verification external quality assessment program and an internal quality control program organized by the National Center of Clinical Laboratories in China.The sigma (σ) values and the quality goal index (QGI) were used to evaluate the performances of different groups,which were divided according to principles and instruments.Results:The majority of participants (88,65.2%) were scored as "improvement needed (σ < 3)",suggesting that the laboratories needed to improve their measurement performance.Only 8.2% (11/135) of the laboratories were scored as "world class (σ ≥ 6)".Among all the 88 laboratories whose σ values were below 3,52 (59.1%) and 23 (26.1%) laboratories needed to improve measurement precision (QGI <8.0) and trueness (QGI > 1.2),respectively;the remaining laboratories (13,14.8%) needed to improve both measurement precision and trueness.In addition,16.1% (5/31) and 15.0% (3/20) of the laboratories in "TOSOH" and "ARKRAY" groups,respectively,were scored as "world class",whereas none of the laboratories in "BIO-RAD" group were scored as "world class".Conclusions:This study indicated that,although participating laboratories were laboratories with better performance in China,the performances were still unsatisfactory.Actions should be taken to improve HbA1c measurement performance before we can include HbA1c assays in diabetes diagnosis in China.

著录项

  • 来源
    《中华医学杂志(英文版)》 |2017年第9期|1079-1084|共6页
  • 作者单位

    National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Beijing Engineering Research Center of Laboratory Medicine, Beijing 100730, China;

    National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Beijing Engineering Research Center of Laboratory Medicine, Beijing 100730, China;

    National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Beijing Engineering Research Center of Laboratory Medicine, Beijing 100730, China;

    National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Beijing Engineering Research Center of Laboratory Medicine, Beijing 100730, China;

    National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Beijing Engineering Research Center of Laboratory Medicine, Beijing 100730, China;

    National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Beijing Engineering Research Center of Laboratory Medicine, Beijing 100730, China;

  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号