The physis of a long bone may get'sandwiched'and crushed between the metaphysis and the epiphysis if it is traumatically loaded along its long axis.Such a physeal injury may lead to complications like angular deformities and growth restrictions and hence,management of such injuries requires adequate planning and attentive execution.Two patients with distal femoral physeal crush injury were treated using a ring fixator such that one ring had the wires passing through the epiphysis and the other through the femoral shaft.On table image intensifier controlled distraction of the crushed physis was done to bring the height of the physis similar to that of the opposite limb.Patients were followed up for more than two years clinically and radiologically.There was no clinical or radiological angular deformity of the operated limbs.MRI scans showed intact physes with no physeal bar formation in either of the two patients.The distraction obtained by the ring fixator appears to have provided ample'breathing space'to the compressed physis and that the growth potential may have been re-gained by the procedure.However,two years is a relatively short duration of follow-up and further follow-up of longer duration and in greater number of patients is needed to gauge the actual effectiveness of the technique used by us.
机译:如果长骨沿长轴受到外伤,可能会被``夹住''并压在干meta端和骨epi之间,这样的骨干损伤可能会导致并发症,例如角畸形和生长受限,因此要对这些损伤进行处理需要适当的计划和周到的执行。使用环固定器治疗两名股骨远端骨被压迫性损伤的患者,以使一个环的金属丝穿过骨and,另一根穿过股骨干。进行了物理检查以使肢体的高度与对侧肢体的高度相似。临床和放射学方面对患者进行了两年以上的随访;手术肢体没有临床或放射学上的角畸变; MRI扫描显示完整的植体,没有两名患者中任一者的骨干都形成。环固定器获得的分心似乎提供了放大作用压缩的身体具有“呼吸空间”,并且该手术可能重新获得了生长潜力。但是,两年的随访时间相对较短,而后续的随访时间较长,且随访时间较长需要患者评估我们使用的技术的实际有效性。

著录项

  • 来源
    《中华创伤杂志(英文版)》 |2017年第6期|366-369|共4页
  • 作者单位

    Department of Orthopaedics, PGIMER, Chandigarh 160012, India;

    Central Institute of Orthopaedics, VMMC and Safdarjung Hospital, New Delhi 110029, India;

    Department of Orthopaedics, PGIMER, Chandigarh 160012, India;

    Department of Orthopaedics, PGIMER, Chandigarh 160012, India;

    Department of Orthopaedics, PGIMER, Chandigarh 160012, India;

    Department of Orthopaedics, PGIMER, Chandigarh 160012, India;

    Department of Orthopaedics, PGIMER, Chandigarh 160012, India;

  • 收录信息 中国科学引文数据库(CSCD);中国科技论文与引文数据库(CSTPCD);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号