In this paper,the mechanism of operation of an inverse circulating thermosyphon evaporator isproposed.The performance characteristics of this novel evaporator have been studied experimentally andtheoretically,The inverse circulating thermosyphon evaporators have higher heat transfer coefficient and longeroperation period in comparison with ordinary circulating ordinary circulating evaporators.