首页> 中文期刊> 《中国生物医学工程学报:英文版》 >Signals Analysis and Clinical Validation of Blood and Oxygen Data in Human Brain

Signals Analysis and Clinical Validation of Blood and Oxygen Data in Human Brain

         

摘要

With a self-made near-infrared analytical instrument to blood and oxygen parameters in human brain, 80 cases in which 20 are healthy persons and 30 are anaesthetised cases and others are patients with heart function lack is taken to examine, and the data of blood and oxygen in brain tissue were collected and analyzed by the method of power spectrum and correlation function. The results indicate that: (1) The average brain oxygen saturation of healthy persons and anaesthetised cases is about 80%, in accord with normal parameter of physiology. Contrastively, the average brain oxygen saturation of patients with heart function lack is 72.8%, which is obviously less than that of healthy persons and anaesthetised cases. The probability of medical statistics is less than 0.01. (2) The shapes of wave of brain blood and oxygen for the healthy person and the anaesthetised case reveal small periodical fluctuations with stable shape and base line, and the trend of increase or decrease of blood and oxygen parameters in brain tissue is synchronous and a phase reversal, but for the patient with heart function lack in a brain oxygen lack state, the shapes of wave are irregular. This is a hint that near infrared light passing through tissue can reflect the intuitionistic change of brain blood and oxygen parameters.(3) The power spectra of brain blood and oxygen for the healthy person and the anaesthetised case has a clear main peak, narrow bandwidth and perfect superposition each other, but the power spectra for the patient with heart function lack in a brain oxygen lack state is on the contrary.(4) The average cross correlation coefficient of brain blood and oxygen for healthy persons and anaesthetised cases is -0.9825±0.1027 close to -1. But the average cross correlation coefficient for patients with heart function lack in a brain oxygen lack state is merely -0.8923±0.1035 which is obviously greater than -1 and the probability of medical statistics is less than 0.01. The clinic experiments have proved that the shapes of waves, the power spectrum and cross correlation coefficient of brain blood and oxygen are useful to analyze the physiological status and changes of blood and oxygen in human brain.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号