In order to solve the problems of present quartz crystal microbalance ( QCM ) measuring instruments, such as high demand for crystal cutting technology and uncomprehensive measurements for crystal parameters, a modified quadrature demodulation-based method was proposed with broadband adaptive response capacity and high frequency resolution. Moreover, it is also capable of measuring both resonant frequencies and dissipation factor D synchronously and continuously. Experimental results at room temperature indicated that the adaptive frequency range was 1-9 MHz while the frequency resolution was less than 1 Hz, measured resonance frequency shifts of crystals in the range scale linearly with the equal thickness increments of poly acrylic acid ( PAA) membrane on the working electrode, and with the volatilization of different solvent factor D is measured continuously and effectively along the time axis. To sum up, compared with traditional ones, this new method has lower material cost and more obtained parameters.%针对目前石英晶体微天平( Quartz crystal microbalance,QCM)仪器所存在的对晶体切割工艺要求过高,测量参数不够全面等问题,在正交解调法的基础上,提出了一种在较宽频率范围内具有自适应功能,测量频率分辨率高,并且可同时连续获取谐振频率和耗散因子D的测试方法。实验表明:室温下,频率测量自适应范围在1~9 MHz且频率分辨率小于1 Hz;随着工作电极聚丙烯酸( Poly acrylic acid,PAA)膜厚度的均匀叠加,测得范围内各晶体频率偏移呈线性变化;随着不同溶剂挥发,D因子测量结果在时间轴上连续有效。与传统方法相比,本方法具有耗材成本低,获取参数丰富等优点。