首页> 外文期刊>生物医学与环境科学(英文版) >Struvite Recovery from Swine Waste Biogas Digester Effluent through a Stainless Steel Device under Constant pH Conditions
【24h】

Struvite Recovery from Swine Waste Biogas Digester Effluent through a Stainless Steel Device under Constant pH Conditions

机译:在恒定pH条件下通过不锈钢设备从猪粪沼气消化池废水中回收鸟粪石

获取原文
获取原文并翻译 | 示例
       

摘要

To investigate the struvite precipitation under constant and non-constant pH conditions and to test a stainless steel device under different operating regimes to maximize the recovery of struvite.Methods The molar ratio of NH4+:Mg2+:PO43-was adjusted to 1:1.2:1.2 and pH was elevated to 9.0.The absorbance measurement was used to trace the process of struvite crystallization.Wastewater and precipitate analysis was done by standard analytical methods.Results The pH constant experiment reported a significantly higher struvite precipitation(24.6±0.86 g) than the non-constant pH experiment(19.8±1.86 g).The SAR ranged from 5.6 to 8.2 g m-2 h-1 to 3.6-4.8 g m-2 h-1 in pH constant and non-constant experiments,respectively.The highest struvite deposit on the device was found in regime 3 followed by in regimes 2 and 4.The highest PO43-(97.2%) and NH4+(71%) removal was reported in the R1 regime.None of the influent Cu2+ or Zn2+ was precipitated on the device.Conclusion A higher struvite yield is evident in pH constant experiments.Moreover,the stainless steel device facilitates the isolation of heavy metal free pure(around 96%) struvite from swine waste biogas digester effluent contaminated with cu2+ and Zn2+ and the highest yield is attainable with the device operating at 50 rpm with agitation by a magnetic stirrer.
机译:Objective To investigate the struvite precipitation under constant and non-constant pH conditions and to test a stainless steel device under different operating regimes to maximize the recovery of struvite. Methods The molar ratio of NH4+:Mg2+:PO43- was adjusted to 1:1.2:1.2 and pH was elevated to 9.0.The absorbance measurement was used to trace the process of struvite crystallization.Wastewater and precipitate analysis was done by standard analytical methods. Results The pH constant experiment reported a significantly higher struvite precipitation (24.6±0.86 g) than the non-constant pH experiment (19.8±1.86 g).The SAR ranged from 5.6 to 8.2 g m-2h-1 to 3.6-4.8 g m-2h-1 in pH constant and non-constant experiments,respectively.The highest struvite deposit on the device was found in regime 3 followed by in regimes 2 and 4.The highest PO43-(97.2%) and NH4+ (71%) removal was reported in the Ri regime.None of the influent Cu2+ or Zn2+ was precipitated on the device. Conclusion A higher struvite yield is evident in pH constant experiments.Moreover,the stainless steel device facilitates the isolation of heavy metal free pure (around 96%) struvite from swine waste biogas digester effluent contaminated with cu2+ and Zn2+ and the highest yield is attainable with the device operating at 50 rpm with agitation by a magnetic stirrer.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号