Reduction of low-order harmonics and new topologies of current source converters.

机译:降低低次谐波和电流源转换器的新拓扑。

获取原文
获取原文并翻译 | 示例

摘要

Two CSCs related issues are investigated. The first is the reductions of Low Order Harmonics (LOH) in Low Switching Frequency (LSF) CSCs. High power CSCs operate with LSF. This is not an ideal scenario for Space Vector Modulation (SVM), resulting in non-characteristics LOH, 5th and 7 th (HD5-7). Researchers have attempted to reduce these harmonics by creating new sequences of space vectors (states) or different sampling techniques. New approaches based on the fact that HD5-7is affected by states ON times calculation process are proposed. Results show that by using a new technique called Record Middle (RM), one can obtain a smaller HD5-7. Also, results for calculating states ON times as the reference vector rotates by new SVM equations show that one can get a significant reduction in HD5-7. Another alternative effective with large overlap periods is minimizing LOHs in LSF-SVM-CSCs with Minimum Harmonic Tracking (MHT) technique. Fuzzy logic dependent states ON times calculation give fixed states ON times adjustment during steady state and fast response. Those techniques allowed the usage of reduced size ac-side filters with high cut-off frequencies.;The second issue is on new hybrid current source converters (HCSCs). Three SCRs and four IGBTs HCSC has similar characteristics, less capital cost and less power losses compared to the 6-switches CSC. Two types of modulation are proposed. The first is Hard Switching Space Vector Modulation technique (HS-SVM). HS-SVM is presenting low maximum modulation index (ma.max), resulting in LOH distortion and requiring multiple mandatory switching inside a cycle. The second modulation technique achieves line-commutation or soft switching (SS) of the SCRs whenever possible, thus being called Soft Switching Space Vector Modulation technique (SS-SVM). SS-SVM increases the ma.max while reducing LOH, the switching frequency and switching losses. Comparisons between the 6-switches CSC and the HCSCs are provided. Cost analysis showing the importance of HCSCs is carried out. A case study is presented to show that the HCSC is economically viable in medium and high power ranges. Besides having lower capital cost, the HCSC can operate with lower power losses than 6-switches CSC.
机译:调查了两个与CSC相关的问题。首先是降低低开关频率(LSF)CSC中的低阶谐波(LOH)。大功率CSC与LSF一起运行。这不是空间矢量调制(SVM)的理想方案,导致非特性LOH为5和7(HD5-7)。研究人员已尝试通过创建空间矢量(状态)的新序列或不同的采样技术来减少这些谐波。提出了基于HD5-7受状态ON时间计算过程影响的新方法。结果表明,通过使用一种称为“记录中间(RM)”的新技术,可以获得较小的HD5-7。同样,通过新的SVM方程计算参考矢量旋转时状态导通时间的结果表明,HD5-7的显着降低。具有较大重叠周期的另一种有效方法是使用最小谐波跟踪(MHT)技术将LSF-SVM-CSC中的LOH最小化。模糊逻辑相关的状态ON时间计算可在稳态和快速响应期间调整固定状态的ON时间。这些技术允许使用具有高截止频率的减小尺寸的交流侧滤波器。第二个问题是新型混合电流源转换器(HCSC)。与6开关CSC相比,三个SCR和四个IGBT HCSC具有相似的特性,更少的投资成本和更少的功率损耗。提出了两种类型的调制。第一种是硬交换空间矢量调制技术(HS-SVM)。 HS-SVM的最大调制指数(ma.max)低,导致LOH失真,并且需要在一个周期内进行多次强制切换。第二调制技术在任何可能的时候都实现了SCR的线换向或软切换(SS),因此被称为软交换空间矢量调制技术(SS-SVM)。 SS-SVM在减小LOH,开关频率和开关损耗的同时增加了最大功率。提供了6开关CSC和HCSC之间的比较。进行了显示HCSC重要性的成本分析。案例研究表明,HCSC在中功率和高功率范围内在经济上可行。除了具有较低的资本成本外,HCSC的运行功耗还比6开关CSC更低。

著录项

  • 作者单位

    Concordia University (Canada).;

  • 授予单位 Concordia University (Canada).;
  • 学科 Engineering Electronics and Electrical.
  • 学位 Ph.D.
  • 年度 2010
  • 页码 211 p.
  • 总页数 211
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号