首页> 外文学位 >Loudness Estimation Through Evoked Responses at Audiometric Frequencies.
【24h】

Loudness Estimation Through Evoked Responses at Audiometric Frequencies.

机译:通过测听频率处的诱发响应进行响度估计。

获取原文
获取原文并翻译 | 示例

摘要

Procedures for evaluating individual loudness functions through tone burst evoked auditory responses---both Tone-Burst Otoacoustic Emissions (TBOAE) and Tone-Burst Auditory Brainstem Responses (TBABR)---have been investigated in the past and have yielded credible results for a limited stimulus frequency range across a wide range of levels. The aim of this work is to investigate this relationship further by expanding the frequency range examined to cover a more full audiometric range and expand the analysis parameters for an objective and thorough analysis process. Evoked-responses (TBOAE and TBABR) were recorded from six normal hearing listeners for 17 different levels and seven frequencies (250, 500, 1000, 2000, 4000, 6000 and 8000 Hz). The recordings were analyzed and the results compared to two psychoacoustic procedures: Cross Modality Matching (CMM) and Magnitude Estimation (ME). Results for TBOAEs show agreement with results from previous studies for 1-kHz and 4-kHz and support the assumption that recorded signals at 500 and 2000 Hz are strong enough for such analysis, while analysis of signals at 250 and 8000 Hz are feasible but suffer from weak OAE response compromising the robustness. Recordings at 4000 and 6000 Hz were too contaminated to produce consistent results due to ear canal resonance. Results for TBABRs also show agreement with results from previous studies for 1-kHz and 4-kHz, and also exhibit consistency throughout the selected frequency range.
机译:过去已经研究了通过音调诱发的听觉响应来评估个人响度功能的程序-音调突发耳声发射(TBOAE)和音调听觉脑干响应(TBABR)-并获得了可信的结果在很宽的水平上限制了刺激频率范围。这项工作的目的是通过扩大所检查的频率范围以涵盖更完整的听力测量范围,并扩展分析参数以进行客观而全面的分析过程,从而进一步研究这种关系。记录了六个正常听众在17种不同级别和七个频率(250、500、1000、2000、4000、6000和8000 Hz)下的诱发反应(TBOAE和TBABR)。分析了录音,并将结果与​​两种心理声学程序进行了比较:交叉模态匹配(CMM)和幅度估计(ME)。 TBOAE的结果与以前的1-kHz和4-kHz研究结果一致,并且支持以下假设:500和2000 Hz的记录信号足以进行此类分析,而250和8000 Hz的信号分析是可行的,但会受到影响弱的OAE响应会损害鲁棒性。由于耳道共鸣,4000和6000 Hz的录音太脏而无法产生一致的结果。 TBABR的结果也与以前的1-kHz和4-kHz研究结果一致,并且在选定的频率范围内也表现出一致性。

著录项

  • 作者

    Sasson, Yonatan.;

  • 作者单位

    Northeastern University.;

  • 授予单位 Northeastern University.;
  • 学科 Health Sciences Audiology.;Engineering Electronics and Electrical.
  • 学位 M.S.
  • 年度 2011
  • 页码 51 p.
  • 总页数 51