首页> 外文学位 >Quantization noise analysis of a closed-loop PWM controller that includes Sigma-Delta modulation.
【24h】

Quantization noise analysis of a closed-loop PWM controller that includes Sigma-Delta modulation.

机译:包含Sigma-Delta调制的闭环PWM控制器的量化噪声分析。

获取原文
获取原文并翻译 | 示例

摘要

Sigma-Delta modulation is a popular noise shaping technique which is used to move the quantization noise out of the frequency band of interest. Recently, a number of authors have applied this technique to a pulse width modulation (PWM) controller for switching power converters. However, previous analysis has not incorporated the effects of analog-to-digital converter (ADC) resolution or feedback control on the Sigma-Delta modulator. In this work, quantization due to ADC resolution and PWM resolution are analyzed, considering the effects of noise-shaping and feedback. A number of simulations have been performed to explore the impact of various design choices on output noise. The study variables included the order of the Sigma-Delta modulator, resolution of ADC, resolution of DPWM, the plant and the compensator. The theoretical model developed is used to generate the expected system Power Spectral Density (PSD) curves for each design choice and simulations techniques are used to validate the analysis. Experimental analysis has been performed on a digital voltage-mode control (VMC) synchronous buck converter and the output voltage PSD curves are generated using the welch method and compared with the theoretical and the simulation results. The experimental PSD curves for the 1st - order modulator match the simulation and theoretical PSD curves. This suggests that the theoretical model is a useful approximation and similar methods can be used to analyze the contribution of the quantizers to the output noise of a closed-loop controller system.
机译:Sigma-Delta调制是一种流行的噪声整形技术,用于将量化噪声移出感兴趣的频带。最近,许多作者已将此技术应用于开关功率转换器的脉宽调制(PWM)控制器。但是,以前的分析尚未考虑到Sigma-Delta调制器上的模数转换器(ADC)分辨率或反馈控制的影响。在这项工作中,考虑了噪声整形和反馈的影响,分析了由于ADC分辨率和PWM分辨率引起的量化。已经进行了许多仿真,以探索各种设计选择对输出噪声的影响。研究变量包括Sigma-Delta调制器的阶数,ADC的分辨率,DPWM的分辨率,设备和补偿器。开发的理论模型用于为每种设计选择生成预期的系统功率谱密度(PSD)曲线,并使用仿真技术来验证分析。在数字电压模式控制(VMC)同步降压转换器上进行了实验分析,并使用Weelch方法生成了输出电压PSD曲线,并将其与理论和仿真结果进行了比较。一阶调制器的实验PSD曲线与仿真和理论PSD曲线匹配。这表明理论模型是一种有用的近似方法,可以使用类似的方法来分析量化器对闭环控制器系统的输出噪声的影响。

著录项

  • 作者

    Balakrishnan, Anupama.;

  • 作者单位

    Missouri University of Science and Technology.;

  • 授予单位 Missouri University of Science and Technology.;
  • 学科 Engineering Electronics and Electrical.
  • 学位 M.S.
  • 年度 2013
  • 页码 185 p.
  • 总页数 185
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-17 11:41:46

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号