首页> 外文学位 >Comparative linear accuracy and reliability of cone beam CT derived 2-dimensional and 3-dimensional images constructed using an orthodontic volumetric rendering program.
【24h】

Comparative linear accuracy and reliability of cone beam CT derived 2-dimensional and 3-dimensional images constructed using an orthodontic volumetric rendering program.

机译:使用正畸体积渲染程序构造的锥束CT导出的二维和3维图像的比较线性精度和可靠性。

获取原文
获取原文并翻译 | 示例

摘要

The purpose of this project was to compare the accuracy and reliability of linear measurements made on 2D projections and 3D reconstructions using Dolphin 3D software (Chatsworth, CA) as compared to direct measurements made on human skulls.;Our results show that for 2D mid sagittal measurements that Simulated LC images are accurate and similar to those from PSP images (except for Ba-Na), and for bilateral measurements simulated LC measurements were similar to PSP but less accurate, underestimating dimensions by between 4.7% to 17%. For 3D volumetric renderings, 2/3rd of CBCT measurements are statistically different from actual measurements, however this possibly is not clinically relevant.;The linear dimensions between 6 bilateral and 8 mid-sagittal anatomical landmarks on 23 dentate dry human skulls were measured three times by multiple observers using a digital caliper to provide twenty orthodontic linear measurements. The skulls were stabilized and imaged via PSP digital cephalometry as well as CBCT. The PSP cephalograms were imported into Dolphin (Chatsworth, CA, USA) and the 3D volumetric data set was imported into Dolphin 3D (Version 2.3, Chatsworth, CA, USA). Using Dolphin 3D, planar cephalograms as well as 3D volumetric surface reconstructions were (3D CBCT) generated. The linear measurements between landmarks of each three modalities were then computed by a single observer three times. For 2D measurements, a one way ANOVA for each measurement dimension was calculated as well as a post hoc Scheffe multiple comparison test with the anatomic distance as the control group. 3D measurements were compared to anatomic truth using Student's t test (P≤50.05). The intraclass correlation coefficient (ICC) and absolute linear and percentage error were determined as indices of intraobserver reliability.
机译:该项目的目的是比较使用Dolphin 3D软件(加利福尼亚州查茨沃思)在2D投影和3D重建上进行的线性测量与在人类头骨上进行的直接测量相比的准确性和可靠性。我们的结果表明,对于2D中矢状位模拟LC图像的测量结果准确且类似于PSP图像(Ba-Na除外);对于双边测量,模拟LC测量值与PSP相似,但准确性较差,将尺寸低估了4.7%至17%。对于3D立体渲染,CBCT测量值的2/3与实际测量值在统计上有所不同,但这在临床上可能不相关;在23个齿状干人头骨上的6个双侧和8个矢状中矢状解剖标志之间的线性尺寸进行了3次测量由多个观察者使用数字卡尺提供二十个正畸线性测量值。颅骨稳定并通过PSP数码头颅测量仪和CBCT成像。将PSP头波图导入Dolphin(美国加利福尼亚州查茨沃思),将3D体积数据集导入Dolphin 3D(美国加利福尼亚州查茨沃斯,版本2.3)。使用Dolphin 3D,生成了平面头颅图以及3D体积表面重建(3D CBCT)。然后,由一个观察者计算三次,分别计算三个模态的界标之间的线性测量。对于2D测量,计算每个测量尺寸的单向方差分析,以及事后Scheffe多重比较测试,以解剖距离作为对照组。使用学生t检验将3D测量值与解剖学真相进行比较(P≤50.05)。组内相关系数(ICC)和绝对线性和百分比误差被确定为观察者内部可靠性的指标。

著录项

  • 作者

    Periago, Danielle R.;

  • 作者单位

    University of Louisville.;

  • 授予单位 University of Louisville.;
  • 学科 Health Sciences Dentistry.;Health Sciences Radiology.
  • 学位 M.S.
  • 年度 2007
  • 页码 86 p.
  • 总页数 86
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-17 11:40:26

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号