This dissertation describes an experimental, analytical, and design investigation on the nonlinear behavior of precast concrete coupling beams, where coupling of reinforced concrete shear walls is achieved by post-tensioning the beams and the walls together at the floor and roof levels. The new coupling system offers important advantages over conventional systems with monolithic cast-in-place beams, such as simpler detailing, reduced damage to the structure, and reduced residual lateral displacements. Steel top and seat angles are used at the beam-to-wall joints to yield and provide energy dissipation.;The results from eight half-scale experiments of unbonded post-tensioned precast coupling beams under reversed-cyclic lateral loading are presented. Each test specimen includes a coupling beam and the adjacent wall pier regions at a floor level. The test parameters include the post-tensioning tendon area and initial stress, initial beam concrete axial stress, angle strength, and beam depth. The results demonstrate excellent stiffness, strength, and ductility of the specimens under cyclic loading, with considerable energy dissipation concentrated in the angles. Compliance of the beams to acceptance criteria is demonstrated, validating the use of these structures in seismic regions. The critical components of the structure that can limit the desired performance include the post-tensioning anchors as well as the top and seat angles and their connections.;The experimental results are also used to validate the analysis and design of the new coupling system. Two different analytical models, one using fiber elements and the other using finite elements, are investigated. In addition, an idealized coupling beam end moment versus chord rotation relationship is developed as a design tool following basic principles of equilibrium, compatibility, and constitutive relationships. The comparisons demonstrate that the analytical and design models are able to capture the nonlinear behavior of the structure, including global parameters such as the beam lateral force versus chord rotation behavior as well as local parameters such as the neutral axis depth at the beam ends. Using these models, the effects of several structural properties (such as beam length) on the behavior of unbonded post-tensioned precast coupling beams is analytically investigated to expand the results from the experiments.
机译:本文描述了预制混凝土耦合梁的非线性特性的实验,分析和设计研究,其中钢筋混凝土剪力墙的耦合是通过将梁和墙在地板和屋顶水平后张在一起而实现的。与具有整体式现浇梁的传统系统相比,新的耦合系统具有重要的优势,例如,结构更简单,结构损坏减少,残余侧向位移减少。在梁到墙的连接处使用钢的顶角和支座角来屈服并提供能量消散。给出了八个非比例尺的无粘结后张预应力耦合梁在反向循环侧向荷载下的半规模试验结果。每个试样包括一个耦合梁和一个在地面上的相邻墙墩区域。试验参数包括张拉后的钢筋束面积和初始应力,初始梁混凝土轴向应力,角强度和梁深度。结果表明,在循环载荷下,样品具有出色的刚度,强度和延展性,并且大量能量散布在各个角度。证明了梁符合验收标准,验证了这些结构在地震区域中的使用。该结构可能会限制所需性能的关键组件包括后张锚,顶角和座角及其连接。实验结果还用于验证新连接系统的分析和设计。研究了两种不同的分析模型,一种使用纤维单元,另一种使用有限元。另外,遵循平衡,相容性和本构关系的基本原理,开发了理想的耦合梁端力矩与弦旋转关系作为设计工具。比较结果表明,分析和设计模型能够捕获结构的非线性行为,包括整体参数,例如梁的横向力与弦旋转行为,以及局部参数,例如梁端的中性轴深度。使用这些模型,通过分析研究了几种结构特性(例如梁的长度)对无粘结后张预应力耦合梁性能的影响,以扩展实验结果。

著录项

  • 作者

    Weldon, Brad D.;

  • 作者单位

    University of Notre Dame.;

  • 授予单位 University of Notre Dame.;
  • 学科 Engineering Civil.
  • 学位 Ph.D.
  • 年度 2010
  • 页码 1255 p.
  • 总页数 1255
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-17 11:37:00

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号