The use of shrouded pin-fin arrays to enhance heat transfer is a common occurrence in many engineering disciplines, from compact heat exchangers in the process industry, to turbine blade cooling in the aerospace industry, to system thermal management in the electronics industry. In this study, experimental methods are employed to study the effect of introducing a small clearance gap between the tips of a pin-fin array and its shroud. Three arrays consisting of tapered cylindrical pin-fins were employed for this purpose. They exhibited pin height-to-diameter ratios (H/D) of 0.5, 0.8 and 1.1, and pin pitch ratios (SL/D and ST/D) of 1.15 and 1.3 respectively. The arrays were heated uniformly and cooled with distilled water in a closed-loop test facility. Heat transfer visualization studies were conducted using thermochromic liquid crystals to estimate convection coefficients as a function of Reynolds number (102 Re 2x104), through a range of clearances (0 to 25 percent of pin height). Adiabatic pressure drop across the pin-fin array was also measured.;In terms of pressure drop performance, the impact of tip clearance was found to be greatest at low Re, ( 5x103), with the effect being significantly diminished by Re = 1.5x104. While the dimensionless pressure drop (f) eventually decreases with the addition of clearance, there appears to be an initial increase in f relative to the non-clearance case for clearances on the order of 5-10 percent of pin height. This increase was seen to be as much as 50 percent at Re on the order of 102.;Observed heat transfer trends were somewhat mixed. In some cases, a modest increase in overall heat transfer was experienced, apparently due to the exposure of the pin tips and their associated area to the cooling fluid. Highest rates of overall heat transfer tended to occur within a clearance range of 10 to 18 percent of pin height. Local heat transfer however was generally seen to decrease. On a constant pumping power basis, the inclusion of clearance was found to generally produce higher heat transfer per unit pumping power for a dimensionless clearance (Cg/D) less than 0.2, when compared to the non-clearance case.
机译:在许多工程领域,从过程工业中的紧凑型热交换器到航空航天工业中的涡轮叶片冷却,再到电子工业中的系统热管理,在许多工程领域中都普遍使用带罩的针翅阵列来增强热传递。在这项研究中,采用实验方法来研究在针鳍阵列的尖端与其护罩之间引入较小的间隙的效果。为此目的,使用了由锥形圆柱销组成的三个阵列。它们的销高径比(H / D)为0.5、0.8和1.1,销距比(SL / D和ST / D)分别为1.15和1.3。将阵列均匀加热,并在闭环测试设备中用蒸馏水冷却。使用热致变色液晶进行传热可视化研究,以估计雷诺数(102

著录项

  • 作者

    Moores, Kevin A.;

  • 作者单位

    University of Maryland, College Park.;

  • 授予单位 University of Maryland, College Park.;
  • 学科 Engineering Mechanical.
  • 学位 Ph.D.
  • 年度 2008
  • 页码 191 p.
  • 总页数 191
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 机械、仪表工业;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号