摘要

Experimental study of greenhouse with heat loss coefficient 8.37W/m2℃ solar heating during the winterwas conducted by a 360m~2 all-glass evacuated tubular collectors. Indoor temperature was kept at around5℃. In the Beijing area of China, where minimum outdoor temperature between mid-December 2000 andmid-February 2001 was lower than -6℃, the average active solar heating ratio was around 10%. However,this figure was raised to 26% beyond that period of time when the minimum outdoor temperature was -4℃.
机译:采用360m〜2全玻璃真空管式集热器进行冬季热损失系数为8.37W / m2℃的日光温室试验研究。室内温度保持在5℃左右。在中国北京地区,在2000年12月中旬至2001年2月中旬之间的最低室外温度低于-6℃时,平均活跃太阳能采暖率约为10%。但是,在最低室外温度为-4℃的那段时间之后,该数字上升到26%。