首页> 外文会议>World Conference on Photovoltaic Energy Conversion;European Photovoltaic Solar Energy Conference;Photovoltaic Science and Engineering Conference;IEEE Photovoltaic Specialist Conference >The neutral point shift of module string and delamination caused by potential-induced-degradation in 50 MWp photovoltaic power plant
【24h】

The neutral point shift of module string and delamination caused by potential-induced-degradation in 50 MWp photovoltaic power plant

机译:50 MWp光伏电站中组件串的中性点移动和由电位引起的退化引起的分层

获取原文

摘要

In this paper, the potential-induced degradation in 50 MWp photovoltaic power plant was investigated. For the first time, we find that the neutral point of voltage in module string moves forward to the positive pole for a PID-affected module string as time goes on. In addition, some PID-related experiments were carried out for field-aged single crystalline silicon solar modules from ARCO Solar. It was found that the delamination in the solar modules is associated with the phenomenon of PID.
机译:本文研究了50 MWp光伏电站中由电势引起的退化。第一次,我们发现随着时间的流逝,模块串中的电压中性点将向前移动到受PID影响的模块串的正极。此外,还对ARCO Solar的场效单晶硅太阳能电池组件进行了与PID相关的实验。已经发现,太阳能模块中的分层与PID现象有关。