首页> 外文会议>World conference on earthquake engineering;WCEE >SEISMIC UPGRADE OF BC HOUSING'S 20 STOREY NICHOLSONTOWER IN VANCOUVER, CANADA
【24h】

SEISMIC UPGRADE OF BC HOUSING'S 20 STOREY NICHOLSONTOWER IN VANCOUVER, CANADA

机译:BC HOUSING在加拿大温哥华的20层NICHOLSONTOWER的地震升级

获取原文

摘要

BC Housing manages an extensive inventory of subsidized housing mostly in the Vancouver area. Theyhave undertaken a program to carry out seismic retrofitting of key aging facilities that have high tenantoccupancy and have been determined to have a high risk of severe damage or collapse for the codespecified earthquake. Design of seismic retrofitting of a permanently occupied residential tower is achallenge that must balance cost, maintain fire safety and minimize disruption to the tenants.This paper presents the retrofit design of a 20 storey concrete tower in Vancouver's 'West End', an areaof dense high rise construction. The concrete shear wall structure was originally constructed in 1969 andhouses some 250 tenants. The initial three-dimensional response spectra analysis, using both SAP2000and ETABS software, determined the load distribution to the existing non-ductile structural componentsand the capability of the existing structural system to contribute to the final retrofit structural system.The retrofit solution included the construction of external concrete shear walls up to the 17th floor, alongwith associated foundation requirements both external to the building and within the basement andstrengthening of the buildings two internal stairwells using continuous steel plates. A key aspect of theretrofit was the continuous vertical sawcutting of the concrete core within the elevator shaft to modify thestiffness in a manner that best suited the overall structural response.Making provision for adequate fire exiting during construction was key. This and other lessons learnedduring the construction period are also presented in this paper with conclusions regarding theeffectiveness of the various aspects of the retrofit with respect to tenant disruption and constructability.
机译:卑诗房屋局主要在温哥华地区管理大量的补贴房屋库存。他们已经执行了一项计划,对租户占用率高的关键老化设施进行地震改造,并确定该地震对于规范规定的地震具有严重破坏或倒塌的高风险。永久居住住宅塔的抗震改造设计是一项挑战,必须平衡成本,保持消防安全并最大程度地减少对租户的干扰。本文介绍了温哥华“西区”(West End)20层高的混凝土塔的改造设计。上升施工。混凝土剪力墙结构最初建于1969年,可容纳约250名租户。最初的三维响应光谱分析使用SAP2000和ETABS软件,确定了现有非延性结构部件的载荷分布以及现有结构系统对最终改型结构系统的贡献能力。直到17楼的外部混凝土剪力墙,以及建筑物外部和地下室内部的相关基础要求,以及使用连续钢板加强建筑物的两个内部楼梯间。改造的一个关键方面是对电梯井道内的混凝土芯进行连续的垂直锯切,以最适合整体结构响应的方式改变刚度。在施工过程中提供足够的火势是关键。本文还介绍了施工期间的这些以及其他经验教训,并得出了有关改造的各个方面对租户破坏和可施工性的有效性的结论。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号