FIELD VERIFICATION OF REFERENCE FLOW AND WATER LEVEL METERS UNDER THE EPA'S ETV PROGRAM

机译:EPA ETV计划下参考流量和水位计的现场验证

获取原文
获取原文并翻译 | 示例

摘要

A field verification of reference flow and water level meters was done as part of thernEnvironmental Technology Verification (ETV) program of the U.S. Environmental ProtectionrnAgency (USEPA), under the “Wet-Weather Flow Technologies” pilot program managed by NSFrnInternational during the summer of 2001. One of the technologies verified under this pilotrnprogram is the “Flow Monitoring Equipment”, which requires the verification of referencernmeters under the terms of the Generic Protocol entitled "Verification of Flowmeters forrnStormwater and CSO Applications in Mid-size Pipes". A full description of the ETV programrnand a copy of the Generic Protocol can be consulted on the following web site:rnhttp://www.epa.gov/etv.rnThis paper presents the testing site and the results of the field verification of the reference metersrnused to verify the vendors’ flowmeters as part of the ETV program. The testing site is a sectionrnof the Quebec Urban Community’s (QUC) interceptor network. The accuracy of three metersrnwas verified: one four-path transit-time flowmeter and two level meters, a bubbler and anrnultrasonic level meter. A total of nine active tests were performed: three tests B (dry-weatherrnflow with and without backflow), C (wet-weather flow without backflow) and D (wet-weatherrnflow with backflow and surcharge conditions). The verification of the accuracy was based on arncomparison with a reference method. The concentrations of blank, concentrated and dilutedrnsamples obtained from the lithium dilution analyses were used to estimate flow rates. Manualrnlevel measurements were used to verify water levels.rnThe Field Testing Organization recognized that the four-path transit-time flowmeter and both thernbubbler and ultrasonic level meters did not meet the accuracy requirements specified in thernGeneric Protocol in order to be validated as the reference meters. Nevertheless, in light of thernresults obtained using the revised flow accuracy margins and considering the unexpectedly lowrnaccuracy of the tracer dilution analysis results, as well as the good fit with the flow ratesrnestimated with the “flow under the gate” equation, the four-path transit-time flowmeter wasrnvalidated as the reference flowmeter to verify the vendors’ flowmeters. Furthermore, in light ofrnthe fact that the performance results are affected by the presence of waves during the two highestrnflow rates of Test C and knowing that the bubbler level meter is less impacted by waves than arernthe manual measurements and ultrasonic readings, the bubbler level meter was validated as thernprimary reference level meter and the ultrasonic as the secondary (or redundant) level meter tornverify the vendors’ flowmeters.
机译:作为美国环境保护署(USEPA)的环境技术验证(ETV)计划的一部分,在2001年夏季由NSFrnInternational管理的“湿天气流量技术”试验计划下,对参考流量表和水位计进行了现场验证。 。在该试验计划中验证的技术之一是“流量监测设备”,它要求根据题为“用于中型管道的Stormwater和CSO应用的流量计的验证”的通用协议的条款对参考仪表进行验证。可在以下网站上查阅ETV程序的完整说明和通用协议的副本:http://www.epa.gov/etv.rn本文介绍了测试站点以及参考文献的现场验证结果meters用于验证供应商的流量计,作为ETV计划的一部分。测试站点位于魁北克城市社区(QUC)拦截器网络的一部分。验证了三米的精度:一台四路转换时间流量计和两台液位计,起泡器和超音波液位计。总共进行了九项主动测试:三项测试B(有和没有回流的干燥天气流动),C(没有回流的潮湿天气流动)和D(有回流和附加条件的潮湿天气流动)。准确性的验证是基于与参考方法的比较。通过锂稀释分析获得的空白,浓缩和稀释样品的浓度用于估算流速。现场测试组织认识到,四通道渡越时间流量计以及气泡计和超声波液位计均未达到通用协议中规定的精度要求,因此可以用作参考水表。但是,考虑到使用修正后的流量精度裕度获得的结果,并考虑到示踪剂稀释分析结果的出乎意料的低准确性,以及与“浇口下流量”方程式估算的流量的良好拟合,四路径过渡时间流量计被验证为参考流量计,以验证供应商的流量计。此外,考虑到在测试C的两个最高流速期间,性能结果受波的存在影响,并且知道起泡器液位计比手动测量和超声波读数受到波的影响小,所以起泡器液位计经验证可以用作主要参考液位计,而超声波可以用作辅助(或冗余)液位计,以验证供应商的流量计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号