CITY OF UNALASKA ULTRAVIOLET DISINFECTION OF A PRIMARY EFFLUENT

机译:非阿拉斯加州主要消毒剂的紫外线消毒剂

获取原文
获取原文并翻译 | 示例

摘要

The City of Unalaska, Alaska was required by the EPA to upgrade their wastewaterrntreatment facilities to meet water quality standards. Treatment at the existing plantrnconsisted solely of fine screening. Outfall dilution models indicated that the plant couldrnnot comply with water quality standards for fecal coliform. To meet water qualityrnstandards, EPA set an effluent limit of 10,000 fecal coliforms per 100 milliliters.rnPreviously, an engineering report was completed to identify the most attractiverndisinfection alternative. This study concluded: (1) disinfection should be by on-siternhypochlorite generation and (2) Ultraviolet (UV) disinfection could not reliably disinfectrnthe primary effluent flow. Detailed construction and operating costs for thernhypochlorite alternative were developed as part of the engineering report. Thesernestimates, $5 million for construction and $148,000/year O&M, indicated UV shouldrnbe re-evaluated.rnThe initial phase of UV re-evaluation included four collimated beam tests. This wasrnfollowed by an on-site three-day pilot test using a medium pressure UV lamp. Thernresults, combined in a dose response curve, showed close correlation between therntwo types of test data. The curve indicated that a dose of 25 mWsec/cm?wasrnnecessary to reduce the effluent fecal coliforms to 1,000 fc/100 ml which was set asrnthe design goal to assure compliance with the 10,000 fc/100 ml effluent standard.rnThe City bid the UV equipment for prepurchase during July 1998 and plans on arnstartup date of October 1999. Bid documents required manufacturers to provide arnsystem that achieved 3 log removal at 2 mgd for a wastewater with a transmittance ofrn11% and 240 mg/l TSS. Bidders were required to provide a 2 year bonded processrnguarantee. The selected UV equipment, PCI's high intensity low pressure system,rncost $332,000. The UV O&M costs are projected to be $36,000/year.
机译:EPA要求阿拉斯加的Unalaska市升级其废水处理设施,以满足水质标准。现有工厂的处理仅由精细筛选组成。排污口稀释模型表明该厂可能不符合粪便大肠菌的水质标准。为了达到水质标准,EPA设定了每100毫升10,000粪便大肠菌的排放限值。以前,已经完成了一项工程报告,以确定最有吸引力的消毒替代品。该研究得出的结论是:(1)消毒应通过次氯酸钠的产生而进行;(2)紫外线(UV)消毒不能可靠地对主要废水进行消毒。作为工程报告的一部分,开发了次氯酸盐替代品的详细建设和运营成本。 Thesernestimates,500万美元的建设费用和14.8万美元/年的运维费用,表明应该重新评估紫外线。紫外线重新评估的初始阶段包括四次准直光束测试。随后是使用中压紫外线灯进行的为期三天的现场先导测试。结果结合剂量响应曲线,显示出两种测试数据之间的密切相关性。曲线表明,必须将25 mWsec / cm2的剂量降低粪便中的粪便大肠杆菌含量至1,000 fc / 100 ml,这是设计目标,目的是确保符合10,000 fc / 100 ml的污水标准。在1998年7月进行预购,计划于arnstart启动日期为1999年10月。投标文件要求制造商提供对于rn11%的透过率和240 mg / l TSS的废水,以2 mgd的速率去除3 log的arnsystem。投标人必须提供为期2年的保税过程保证。选定的紫外线设备,PCI的高强度低压系统,价格为33.2万美元。 UV O&M成本预计为每年36,000美元。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号