This paper discusses for a bi-directional isolated DC/DC converter using series voltage compensation. The proposed converter consists of a high efficiency resonance full-bridge converter and a series converter. The proposed circuit regulates the output voltage by using the series converter, which provides only the differential voltage between the input voltage and the output voltage that is closed to the nominal voltage, since only the resonance converter will operate. In this paper, four types of the auxiliary circuits are investigated using the loss calculation. The relationship between the loss element and efficiency characteristics is clarified. The validity of the proposed circuit was confirmed by experimental results, which converts 48-V to 380-V at 1kW, with a maximum efficiency of 95% at 1 kW at the nominal input voltage region.
机译:本文讨论了使用串联电压补偿的双向隔离式DC / DC转换器。拟议的转换器包括一个高效谐振全桥转换器和一个串联转换器。所提出的电路通过使用串联转换器来调节输出电压,该串联转换器仅提供输入电压与接近标称电压的输出电压之间的差分电压,因为只有谐振转换器可以工作。在本文中,使用损耗计算研究了四种类型的辅助电路。阐明了损耗因素与效率特性之间的关系。实验结果证实了所提出电路的有效性,该实验结果在1kW下将48V转换为380V,在标称输入电压范围内在1kW下的最大效率为95%。