Hydroelectric developments with gated spillways and earthfill retention dams, quite vulnerable to overflowing, represent a large share of dam construction in Romania and raise major safety and risk problems. Usual regulatory principles and methods for gated spillway dimensioning take into account empirically the spillway peculiarities as compared to the ungated spillways from the safety point of view, but neglect significant aspects. There are suggested analysis and decision procedures based on determining the (binominal type) probabilistic distribution of the capable discharge of a spillway equipped with identical gates, starting from the unavailability probability (handling incapacity) of a gate and from the concept of checking the structure under limit conditions of breakdown induced by overflowing. Results show that value of. gate unavailability probability has a decisivej importance that leads to the necessity of providing a number of additional bays for taking over the discharges corresponding to the non-operating gates at any handling (opening) test. Reliability of spillway hydromechanical equipment (gates) is a primordial and decisive problem for work safety, much more important than that related to other elements, requiring a perfectly legitimate concern and financial effort.
机译:带有闸门溢洪道和填土坝的水力发电项目非常容易发生溢流,在罗马尼亚的水坝建设中占很大比重,并引发了重大的安全和风险问题。从安全的角度来看,门控溢洪道尺寸确定的常规监管原则和方法从经验上考虑了溢洪道的特性,与非开孔溢洪道相比,却忽略了很多方面。根据确定具有相同闸门的溢洪道的有能力排放的(二项式)概率分布,从闸门的不可用概率(处理能力丧失)和检查结构的概念出发,提出了建议的分析和决策程序。限制由溢出引起的击穿条件。结果表明其价值。闸门不可用的概率具有决定性的重要性,这导致有必要在任何处理(开启)测试中提供许多额外的隔间,以接管与非闸门相对应的排放。溢洪道水力机械设备(闸门)的可靠性是工作安全的首要问题,是决定性的问题,比其他方面的问题更为重要,需要绝对正当的考虑和财政上的努力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号