Objectives: To compare the permeability of human dentin and a porous ceramic with two different compositions of perfusion fluid, in vitro. Methods: Dentin discs were cut from extracted third molar at a level close to the pulp chamber and ceramic discs were cut from a porous ceramic block. The convective permeability of the discs was measured in a fluid transport model using de-ionised water or 1:3 diluted bovine serum and the hydraulic conductance was determined. Results: In the negative controls, no flow was detected. The hydraulic conductance values for the dentin discs and the ceramic discs when water was used as the perfusion fluid were 0.069±0.023and 0.047±0.019μl min~(-1) cm~(-2) cm H_2O~(-1), respectively. When the discs were perfused with the diluted bovine serum the mean (standard error of the mean) hydraulic conductance values for the dentin and the ceramic discs were 0.036±0.016 and 0.012±0.0055 μ1 min~(-1)cm~(-2) cm H_2O~(-1), respectively. Conclusion: Basing on the modern technique it is possible to fabricate discs of hydroxylapatite ceramic to act as substitutes for dentin barriers in cytotoxicity test.
机译:目的:比较人牙本质和多孔陶瓷与两种不同灌注液成分的渗透性。方法:在接近牙髓腔的位置,从提取的第三磨牙上切下牙本质片,并从多孔陶瓷块上切下陶瓷片。在使用去离子水或1:3稀释牛血清的流体传输模型中测量了圆盘的对流渗透性,并确定了水力传导率。结果:在阴性对照中,未检测到血流。以水为灌注液时牙本质牙盘和陶瓷牙盘的水力传导率分别为0.069±0.023和0.047±0.019μlmin〜(-1)cm〜(-2)cm H_2O〜(-1) 。当用稀释的牛血清灌注椎间盘时,牙本质和陶瓷椎间盘的均值(均值的标准误差)为0.036±0.016和0.012±0.0055μ1min〜(-1)cm〜(-2) cm H_2O〜(-1)。结论:在现代技术的基础上,可以制备羟基磷灰石陶瓷片,以替代其在细胞毒性试验中对牙本质屏障的作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号