Water leakage has occurred in numerous EIFS-clad residences in the U.S. Field investigations of North Carolina homes indicate that deficiencies within and between various building components are allowing water leakage. Moisture behind EIFS claddings has jeopardized the in-service durability of the EIFS as well as other building components. A brief history of EIFS provides a framework for understanding the water leakage problems in residential construction. A classification of leakage sources identified to date in the North Carolina investigations is provided. Window-related leaks are discussed, and a remedial detailing for the typical interface between EIFS and windows is provided.
机译:在美国,许多EIFS覆盖的住宅中都发生了漏水。对北卡罗来纳州房屋的现场调查表明,各种建筑组件内部和之间的缺陷导致漏水。 EIFS覆层后面的湿气损害了EIFS以及其他建筑组件的使用寿命。 EIFS的简要历史为了解住宅建筑中的漏水问题提供了框架。提供了迄今为止在北卡罗莱纳州调查中确定的泄漏源分类。讨论了与窗口有关的泄漏,并提供了EIFS和窗口之间典型接口的补救细节。